- ProMinent user manual metering pump S2Ba, S2Ca

Page 54
ProMinent
®
Dulcodes UV-Desinfektionsanlage
Troubleshooting
Green LED indicator (operating display) is not lit
Cause Incorrect or no mains voltage.
Remedy Use the recommended mains voltage as given in the voltage specification on the
nameplate.
Error Messages
Red LED display is lit, “Error” and “MINIM” flash in the display
Cause Fluid level in the chemical storage tank has reached liquid level low, stage 2.
Remedy Fill the chemical supply container.
Red LED display is lit, “Error” and “ANALG” flash in the display
Cause S2Ca is in analogue operating mode, a fault routine has been programmed in the ANALG
menu and the operating current has fallen below 3.8 mA.
Remedy Remedy low operating current.
Switch fault routine OFF (see section 7.4.2.).
Red LED display is lit, “Error” and “CNTCT” flash in the display
Cause S2Ca is in contact or batch operating mode and the extended function memory has been
set.
In addition a very large factor has been entered, too many contacts have been input or the P-
key has been pressed too often, resulting in an overflow of the stroke memory.
Remedy Press the P-key, saved data will be deleted.
Change S2Ca set up.
Red LED display is lit, “Error” and “FLOW” flash in the display
Cause Dosing monitor not properly connected.
Remedy Connect dosing monitor properly.
Press P-key.
Cause Dosing monitor has reported more defective strokes than have been set in the FLOW menu.
Remedy Press P-key.
Investigate the cause and remedy.
Red LED is lit. “Error” appears in the display and “MOTOR” is flashing
Cause The motor is not operating accurately because the backpressure is too high.
Remedy Reduce backpressure.
Press the P key (reset key).
Cause The motor is overheating.
Remedy Check ambient temperature (max. 40 ºC).
Allow motor to cool down.
Press the P key (reset key).
Cause Other motor fault.
Remedy Call ProMinent.
Press the P key (reset key).
Red LED is lit. “Error” appears in the display and “TEMPERATURE” is flashing
Cause The temperature in the pump housing is too high because the ambient temperature is too high.
Remedy Reduce ambient temperature.
Allow motor to cool down.
Press the P key (reset key).
Cause The temperature in the pump housing is too high because the pump is consuming too much power.
Remedy Check installation, rectify if necessary.
Allow motor to cool down.
Press the P key (reset key).