User's Manual

Tele
Eye
RX
User
Guide Page 115
Event Handling
For Exit Zone :
The exit delay is the period of time for leaving a surveillance zone without making false alarm
(i.e. Alarm 1, Alarm 2, Alarm 3 and Alarm 4). The purpose is to let the user / installer have
enough of time to leave the surveillance zone after the transmitter is armed. User / installer can
set the delay time for each alarm.
The detail procedure is as below:
1) user arms the system
2) the alarm moves to exit delay
3) the 1
st
trigger is made by Alarm1 (i.e. user leave the surveillance zone and the exit delay
time begin)
4) 2
nd
, 3
rd
and 4
th
trigger are made and each exit delay starts respectively
5) user waits for any alarm exit delay to expire.
For example, if the time for leaving the surveillance zone is about 8 minutes, user should adjust
the delay time so that Delay 1 = leaving time between transmitter and Alarm 1, Delay 2 =
leaving time between transmitter and Alarm 2, Delay 3 = leaving time between transmitter and
Alarm 3 and Delay 4 = 8 minutes. The alarm will be activated after the exit delay expired. Note
that if user enables recording action, recording action is automatically activated during exit
delay.
Tel
e
Eye RX
ARM
Surveillance zone
Alarm 4Alarm 3Alarm 2Alarm 1
Delay4Delay3Delay2Delay1
Exit
Time line