User's Manual

Tele
Eye
RX
User
Guide Page 47
Setup
Tele
Eye RX for Broadband or Narrowband
Internet Connection with Dynamic IP
Step 11a: Configure
Tele
Eye RX transmitter IP setting through CCTV Monitor
RG59 cable
Power Adapter
Ethernet Socket
Tel e
Eye RX
Cameras
192.168.0.2
CCTV
Monitor
RG59 cable
Press the “Menu button such that the
OSD main menu
pops up on the monitor.
Use “Up or “Down button to
select [SETUP] option and press “Enter
button.
Select[CONNECTION]option and press
Enter
button
Select [TCP/IP] option and Press “Enter
button
Select [IP] option and press “Enter
button. IP address consists of four fields.
Each field can assign a number from 0 to
255.
SETUP MENU
VIDEO . . .
RECORDING . . .
SWITCHES . . .
DATE / TIME . . .
CONNECTION . . .
EVENT HANDLER . . .
TRANSMITTER . . .
RESTORE FACTORY SETTING ENTER
CONNECTION
TCP / IP
MODEM
TCP / IP
IP 192.168.0.2
PORT 1024
SUBNET MASK 255.255.255.0
ENABLE GATEWAY NO
GATEWAY 0.0.0.0
ENABLE DNS NO
PRIMARY DNS 0.0.0.0
SECONDARY DNS 0.0.0.0
SURELINK