User's Manual

10
Mounting and Care
The Pressure Scout unit comes with an integrated pressure sensor with a ½MNPT process fitting.
The Scout is mounted directly to the pressure source. It is important to mount the Scout so it is vertically
orientated with the pressure fitting facing down.
Internal Lithium Battery Replacement
Battery Packs can be changed with the node in place.
1 Unscrew the cover from the base.
2 Unplug the battery from the PCB, by depressing the locking clip on the connector.
3 Remove/replace battery
4 Connect the battery to the main PCB battery connector.
5 Install the enclosure cover.
WARNING: Use of any battery other than the SignalFire part number 810-0030-01 (1BIS) will
impair the protection provided by the equipment.
Cleaning Instructions
The outside of the enclosure may be cleaned with water, mild soap, and a damp cloth as needed. High pressure
washing is not recommended.
WARNING: Electrostatic Discharge Hazard! Care must be taken to avoid the potential of creating a
change on the enclosure or antenna. Do not wipe with a dry cloth. Do not brush against the
enclosure with clothing or gloves.
SignalFire Telemetry
Rev 1.1