CATALOGUE Safety Requirements 01 Warnings/precautions 02 Chapter I Operation Keys And Parts Introduction 05 Display Menu Introduction 09 Introduction To Splice Interface 10 Chapter II Software Download 16 Software Bluetooth Connection 17 Screen Menu Function On/off 19 Chapter III Smart Lock 22 Chapter IV Toolbox Introduction 24 Chapter V Arc Calibration 25 Chapter VI Fiber Stripping And Put Into Holder 26 Chapter VII Replace Electrode 27 Chapter VIII Activate Electrode 29 Chapter
SAFETY REQUIREMENTS At any stage of operation on the optical fiber fusion splicer, you must take the following general safety precautions. Not take these warnings and precautions or not comply with the warnings which described in this manual, would violate the fusion splicer design, manufacture and use of safety standards.
WARNINGS/PRECAUTIONS storage (storage time less than or equal to 6 months) is: -20℃~60℃. 4.In order to ensure the safety of charging, the charging temperature range of lithium battery inside the welding machine is O℃~ 40℃. 5.If the battery charging is abnormal or the battery display is abnormal, you can try to activate the battery manually.
CHAPTER I OPERATION KEY COMBINATION FUNCTION Introduction of operation keys and parts ORESET Press the reset key to reset the propulsion motor, adjustable motor, and focusing motor to their original. When the Reset button light is on, it indicates the reset is in process. If it turns off within 5 seconds automatically that means the reset is successful, otherwise the reset is failed.
OPERATION KEY COMBINATION FUNCTION 08 Camera LED: X Y Camera LED:two report an error,Please check whether the red light above the electrode is bright and dim(see electrode replacement for specific operations)If the fault persists,Please contact the after-sales service. 09 RTC RTC Report an error,please check again. If the error is still reported, please contact after-sales service.
DISPLAY MENU INTRODUCTION INTRODUCTION TO SPLICE INTERFACE Heating time Optical power display area ICON NAME FUNCTION Normal mode Normal Splicing Mode For The Machine Splicing process pause When the function is on the splicing machine will stop the final splicing process after in the completion of the fiber focus, end face detection and fiber alignment. Please then press the “Continue “button to perform the arc discharge and the subsequent splicing process.
INTRODUCTION TO SPLICE INTERFACE Intelligent prompt and fiber state prompt solution Ⅰ Intelligent prompt The red symbol displayed at the bottom left of the LCD. Camera fault: first clean the objective lens, and then upgrade the welding machine firmware to the latest version. If the fault still exists, please conduct self-inspection of the welding machine to confirm whether the camera fails (please refer to daily maintenance for specific operation).
INTRODUCTION TO SPLICE INTERFACE Ⅱ fiber state prompt The optical fiber symbol in the middle below the LCD, two blue and white bars represent V groove, the small triangle in the middle represents electrode tip, and the black bar flashing on the blue and white bars represents optical fiber. The distance from the optical fiber mark to the middle small triangle (electrode tip) is different, representing different states of optical fiber.
INTRODUCTION TO SPLICE INTERFACE The test is fiber passing Fiber passing means screen display is a complete fiber, take out fiber can be normal. Sometimes errors may be reported due to dirty lens or fog, and the lens can be restored after cleaning (see daily maintenance for specific operations). Failed to identify qualified optical fiber or no optical fiber detected A Red Cross is displayed on the v-slot mark to indicate that no fiber has been identified or no fiber has been laid.
SOFTWARE BLUETOOTH CONNECTION SOFTWARE BLUETOOTH CONNECTION The mobile phone is not needed when splicing, The mobile APP can be used to turn on off the machine menu, arc calibration remote control smart lock. etc You can also learn various operations in the app, as well as contact after-sales support, or you can update the mobile app and connect to the machine to synchronize updates Phone settings 2. Android phone to open the bluetooth permission function is as follows 1.
SOFTWARE BLUETOOTH CONNECTION SCREEN MENU FUNCTION ON/OFF Turn on the phone bluetooth, open the phone app, set the machine panel menu after establishing the connection, and machine will update at the same time. The splicing operation does not require phones, the phone App is only for machine menu settings, and splicer machine to store data.when the data is exported to phone App, the users can also get support through the APP and after-sales service.
SCREEN MENU FUNCTION ON/OFF CHAPTERⅢ SMART LOCK When the settings are saved, the display icon will be highlighted darkened accordingly.otherwise please check whether the bluetooth is properly connected.c Smart Lock Purpose: to facilitate management or owner's effective management of the splicer machine's use period or the number of splicing. Typical applications such as rental business.
SMART LOCK CHAPTER IV TOOLBOX INTRODUCTION A Device Can Only Be Bound To One Mobile Account At The Same Time. To Bind Other Mobile Phones. You Need To Unbind Current Account First. Lock catch Tool layer Platform for fiber cleaving Accessory layer 3. Click on the settings icon to enter. 4. Save after personalization settings. 23 5. Click on the"Smart lock management "button to see all the splicing machines controlled by this mobile phone account.
CHAPTER V ARC CALIBRATION CHAPTER VI FIBER STRIPPING AND PUT INTO HOLDER ARC Calibration: According to the local ground elevation, temperature, moderate and other environmental factors to match the most suitable discharge ARC, in order to obtain the bestsplicing effect, we strongly recommend you to do arc calibration when it is the first time to use the new machine, the seasonal changes, the use place changes, or you replaced the electrodes;discharge correction should be done after changing the type of fi
CHAPTER VII REPLACE ELECTRODE REPLACE ELECTRODE Electrode replacement must use the genuine original electrode designed for this machine from factory. When the number of electrode is used close to 3000 times, the machine will remind you to replace it. When it reaches to 3000 times, it is necessary to replace the electrod and activate it then you can use again(see page 29 ACTIVATE ELECTRODE). Otherwise it may affect the splicing quality, or even shut down the program automatically, and could not splice.
CHAPTER Ⅷ ACTIVATE ELECTRODE ACTIVATE ELECTRODE PS. The electrodes on the new machine do not need to activate we have activated before ex-factory. Only when the electrodes life on the machine is expired in the future mand then you need to replace activate the electrode hen the electrode is used up to 3000 times, you need to replace the electrode and activate it. You need to use APP software "Signalfire2" install in your phone and activate the electrodes.
CHAPTER IX POWER METER AND OPTICAL MODULES Effect easure connection loss, verify continuity, and help evaluate fiber link transmission quality POWER METER AND OPTICAL MODULES Optical power meter and VFL parameter settings The fusion splicer screen displays the measurement results Optical power meter input VFL output 2.Turn on the power meter and light module, set and return. 1.The user logs in to the "signalfire2" app and connects to the machine Bluetooth.
CHAPTER X DAILY MAINTENANCE Ⅰ.Pay attention to dustproof and remove dust Bare fiber positioning groove, electrodes and microscopes must be kept clean and windshield cover should be closed when not in operation 1. V-groove Cleaning If the V-groove has dirty and can not hold the fiber properly, which will cause very high splicing loss. Thus in the daily work, you should always check the V-groove and regular cleaning V-groove. Follow the steps below to clean the V-groove.
DAILY MAINTENANCE DAILY MAINTENANCE Ⅴ.Troubleshooting and solutions The table lists a general troubleshooting method for the user reference. When the user can not solve the situation, please contact with the suppliers directly. Troubleshooting Reason Solutions 1.Not power on 2.Fiber does not enter V-groove or v-groove has dirty 3.The length of the fiber is too short or broken 4.The align mechanism is not initialized 5.No signal detected for close windshield cover 1.Press the power key 2.
DAILY MAINTENANCE DAILY MAINTENANCE 4.The bottom left corner of the machine shows a red box with a red dot in the middle -- this is a focus failure. Wipe the lens with a cotton swab, clean the V slot, press the reset key on the far left of the machine and replace the fiber. 1.
DAILY MAINTENANCE DAILY MAINTENANCE 7.One side of the optical fiber is up or down and cannot be restored by cleaning the V slot and resetting -open the mobile phone APP and connect it to the machine, then select the welding setting -- operation mode -- factory core adjustment, and select manual adjustment when returning. If it is on the left, adjust it to the center of the screen by pressing the up and down triangle button on the left, and vice versa. 8.
DAILY MAINTENANCE DAILY MAINTENANCE 9.Easily broken fiber -- -- if it is broken from the welding point, generally is the current is not appropriate, redo the discharge calibration on the line. If it is from the position of the fixture fracture is caused by the quality of optical fiber, this case leather fiber and fiber optic cable will need to put the fiber rubber coating layer left two to three millimeters not peeling, clamping device pressure down, pressure on the coating layer can be.
CHAPTER XI LIGHTING AND POWER SUPPLY Lighting: night lighting is convenient for construction work Mobile phone charging: the device can reverse the power supply to the mobile phone Mobile phone charging diagram Lighting use diagram 43