Air Kit Installation

1Air Massage Kit Installation Instructions
AIR MASSAGE KIT INSTALLATION INSTRUCTIONS
GETTING STARTED
TOOLS AND MATERIALS:
BEFORE YOU BEGIN
We recommend consulting a professional if you are
unfamiliar with installing bathroom fixtures and
plumbing. Signature Hardware accepts no liability for
any damage to the floor, walls, plumbing, or personal
injury during installation.
Observe all local plumbing and building codes.
Unpack and inspect all items for damage. If any damage
is found, contact our Customer Relations team at
1-866-855-2284.
*not included
Ensure that you have gathered all of the required
materials that are needed for the installation.
Keep the air kit components easily accessible for any
future mainetenance that may be necessary.
STEP 1:
ELECTRICAL REQUIREMENTS
1. Before beginning electrical installation make sure
that the electricity is disconnected at the fuse box.
2. Wiring should be permanent. Do not use an
extension cord. Have the electrical part of the
installation done by, or approved by, a qualified
electrician.
3. Determine a location to mount your blower motor.
The blower should be mounted within 5’ of the tub in an
uninsulated location, and easily accessible. There
should be sufficient air space around the motor for
proper functionality. If you are mounting the blower
behind a wall or below the floor, you must have an
access panel of approximately 30”x15” to allow access
for servicing.
4. Use the factory pre-installed type SJ wire to connect
to junction box. Run a separate 120V, 60Hz, 15A G.F.I.
(Class A protected) electric circuit from the main fuse
box to the junction box. Use a 14 gauge three
conductor cable (2 wires plus ground) in connections up
to 100 feet (30, 4m) from the main fuse box. Refer to
your local electrical code if the distance between the
tub and the main fuse box is more than 100 feet.
5. Use the following wiring diagram as a guideline when
preparing the electrical components.
Tape Measure*Marker*
Drill*
Screwdriver*
MAIN FUSE BOX
WHITE
BLACK
GREEN
120V, 60Hz, 15A
GROUND FAULT
CIRCUIT INTERUPTER
Class A
JUNCTION
BOX
MAIN BLOWER