Installation Sheet

28
1.855.715.1800
PROBLEM CAUSES SOLUTION
Motor will not start
- Circuit breaker may be tripped
- Loose/Bad wire connection
- GFCI is tripped
- Incorrect electrical installation
- Jets are closed
- Lose/Bad wire connection
- Incorrect Amp usage
- Air supply to motor
- Jets are closed
- Suction/ strainer may be clogged
- Air valves are closed
- Jets are closed
- Pump does not have space
to operate
- Debris in pump
- Incorrect Amp usage
- Clogged pipe
- Incorrect electrical installation
Water leaks - Leak in the plumbing
TROUBLESHOOTING
Low Water Flow
Motor overheating and

Pump/motor operates
function
Motor makes humming

- Make sure it is a 20 Amp circuit breaker with nothing else tied to the circuit
- Check for incorrect or lose wire connections, and pump/heater has
been properly grounded
- Reset if necessary
- Insure each motor/ in-line heater uses its own 20 Amp circuit breaker
and GFCI plug

- Check for incorrect or loose wire connections
- Check for low voltage supply
- Make sure motor gets fresh air supply and vents are not clogged
- Open jets fully

- Open all air control valves
- Make sure jets are fully open
- Make sure the motor shaft turns free
- Check for jammed impeller or an obstruction on the (volute) casing

- Check for clogged plumbing lines
- Check for low voltage

secured, Hand tighten only, Do not use any tools
- Make sure the o-ring is properly seated and not damaged
ACRYLIC BATHTUB
BAÑERA ACRÍLICA
BAIGNOIRE EN ACRYLIQUE
SKU: 948049, 948261, 948047, 948260, 948046, 948270, 948268, 948052