30" (762 mm)
finished width
CUTOUT DIMENSIONS – FLUSH INSTALLATION
SINGLE COLUMN
4"
(102 mm)
finished
return*
TOP VIEW
INSTALLATION CLEARANCES – FLUSH INSTALLATION
SKSCF3001P
30-INCH INTEGRATED
COLUMN FREEZER
**
Varies depending on the
thickness of the custom
cabinet panel. The door
panels in the optional
Signature Kitchen Suite
stainless steel door panel
kit are 3/4" (19 mm) thick.
Door handle must be
added to this dimension.
*
1 3/8"
(35 mm)
A minimum 4" (102 mm) finished return that matches the cabinet
exterior is recommended on all sides and the top of the cutout
opening. The shaded area will be visible after installation.
*
3/4"
(19 mm)**
115°
90°
1/8"
(3 mm)
1/8"
min.
min.
(3 mm)
29 3/4"
(756 mm)
30" (762 mm)
25"
(635 mm)
13 7/8"*
(352 mm)
31 1/2"
(800 mm)
1 1/4"*
(32 mm)
5"
(127 mm)
electrical
location
4"
(102 mm)
water location
25" (635 mm)
min. depth
84"
(2134 mm)
CUTOUT DIMENSIONS – FLUSH INSTALLATION
Notes
Freezer can be installed ush with 3/4" custom panel or
optional stainless steel panel kit.
With a 25" (635 mm) cutout depth, the front face of
the f
reezer ts ush with 25" (635 mm) depth adjacent
cabinets.
Electrical
A 115V, 60Hz., 15 amp power supply is required. An
individual properly grounded branch circuit or circuit
breaker is recomm
ended. Install a properly grounded
3-prong electrical receptacle recessed into the back wall.
Electrical must be located on rear wall as shown.
Note: GFI (ground fault interrupter) is not rec
ommended.
Water Line
A cold water supply is required for automatic icemaker
operation. Water pressure must be between 20 and
120 p.s.i.
Tubing should be long enough to extend to the front of
the freezer. Allow enough tubing to accommodate a bend
leading into the water line connection.
Water line can enter an opening throu
gh oor or back wall.
Install a shut-o valve between the icemaker water valve
and cold water supply in the home.
SINGLE COLUMN
Notes
Door Swing Clearances – The installation must allow for
clearances t
o adjacent walls or cabinets. This freezer is
equipped with a 2-position door stop. The factory-set 115°
door swing can be adjusted to 90° if clearance to adjacent
cabinets or walls is restricted.
Door Handle Clearances – The Door Handle depth must
be added to the dimension noted to determine the total
clearances required from adjacent cabinets or walls. This
clearance will vary depending o
n the custom handle used.
When using the Stainless Steel Door Panel Kit w/Handle or
the Brushed Aluminum Handle (optional accessories), the
door handle clearance with door open 115° is 16" (406 mm)
.
INSTALLATION CLEARANCES – FLUSH INSTALLATION
TOP VIEW
30" (762 mm)
finished width
CUTOUT DIMENSIONS – FLUSH INSTALLATION
SINGLE COLUMN
4"
(102 mm)
finished
return*
TOP VIEW
INSTALLATION CLEARANCES – FLUSH INSTALLATION
SKSCF3001P
30-INCH INTEGRATED
COLUMN FREEZER
**
Varies depending on the
thickness of the custom
cabinet panel. The door
panels in the optional
Signature Kitchen Suite
stainless steel door panel
kit are 3/4" (19 mm) thick.
Door handle must be
added to this dimension.
*
1 3/8"
(35 mm)
A minimum 4" (102 mm) finished return that matches the cabinet
exterior is recommended on all sides and the top of the cutout
opening. The shaded area will be visible after installation.
*
3/4"
(19 mm)**
115°
90°
1/8"
(3 mm)
1/8"
min.
min.
(3 mm)
29 3/4"
(756 mm)
30" (762 mm)
25"
(635 mm)
13 7/8"*
(352 mm)
31 1/2"
(800 mm)
1 1/4"*
(32 mm)
5"
(127 mm)
electrical
location
4"
(102 mm)
water location
25" (635 mm)
min. depth
84"
(2134 mm)
SKSCF3001P
30-INCH INTEGRATED COLUMN FREEZER
CUTOUT DIMENSIONS – FLUSH
INSTALLATION SINGLE COLUMN
A minimum 4" (102 mm) finished return that matches the cabinet *
exterior is recommended on all sides and the top of the cutout
opening. The shaded area will be visible after installation.
Notes
Freezer can be installed flush with 3/4" custom panel or
optional stainless steel panel kit.
With a 25" (635 mm) cutout depth, the front face of the
freezer fits flush with 25" (635 mm) depth adjacent
cabinets.
Electrical
A 115V, 60Hz., 15 amp power supply is required. An
individual properly grounded branch circuit or circuit breaker
is recommended. Install a properly grounded 3-prong
electrical receptacle recessed into the back wall. Electrical
must be located on rear wall as shown.
Note: GFI (ground fault interrupter) is not recommended.
Water Line
A cold water supply is required for automatic icemaker operation. Water
pressure must be between 20 and 120 p.s.i.
Tubing should be long enough to extend to the front of the
freezer. Allow enough tubing to accommodate a bend leading
into the water line connection.
Water line can enter an opening through floor or back wall.
Install a shut-off valve between the icemaker water
valve and cold water supply in the home.
INSTALLATION CLEARANCES – FLUSH
INSTALLATION TOP VIEW
Door handle must be * added to
this dimension.
** Varies depending on the thickness
of the custom cabinet panel. The
door panels in the optional Signature
Kitchen Suite stainless steel door
panel kit are 3/4" (19 mm) thick.
Notes
Door Swing Clearances – The installation must allow for
clearances to adjacent walls or cabinets. This freezer is
equipped with a 2-position door stop. The factory-set 115° door
swing can be adjusted to 90° if clearance to adjacent cabinets
or walls is restricted.
Door Handle Clearances – The Door Handle depth must be added to the
dimension noted to determine the total clearances required from adjacent
cabinets or walls. This clearance will vary depending on the custom
handle used. When using the Stainless Steel Door Panel Kit w/Handle or
the Brushed Aluminum Handle (optional accessories), the door handle
clearance with door open 115° is 16" (406 mm).
Page 3 of 5