Quick Installation Guide

Transceiver Dimensions (in/mm) Installation
Conguring Sensor Parameters
Step 1: Drill 2.5-inch hole in ceiling. It may be
more practical to remove the ceiling tile and
drill from the backside depending on material.
Step 3: Compress spring clips on sensor and
insert into ceiling hole.
Step 5: Connect the wires from the sensor to the LED Driver in the xture. Connect the white
wire from the sensor to the brown (SR-) terminal on the driver. Connect the red wire from the
sensor to the purple (SR+) terminal on the driver. Follow xture manufacturer’s instructions for
accessing the driver.
EasySense operates upon energization with
no further commissioning. See Transceiver
datasheet for sensor presets and
parameters that can be changed during
installation. Refer to “Operation and
Configuration via Mobile App” on last page
for further details.
Step 2: Feed wires from sensor into ceiling
hole. Wire length provided is 36-inches.
Cable jacket provided is plenum-rated.
Add additional wire length if necessary
(18AWG solid wire recommended).
Step 4: Sensor will clamp into place. Turn
sensor to appropriate position.
Notes:
1. For use in non-fire-rated installations only.
2. Remove power from fixtures/drivers before performing any electrical work.
3. Up to (4) drivers maximum can be connected to (1) EasySense. Polarity must be maintained.
Ø 2.480 (63) REF.
Ø 2.913 (74) REF.
1.811 (46) REF.
1.240 (31.5) REF.