Programming instructions

23
In-Home bus Video
Multiple line system
Function
Up to 29PCusers (Software Clients)
in a network can be called per
SII650-.... In a multiple-line system,
several lines are connected. The line
address must be set the same at
each BVNG650-..., SIVS610-... and
SII650-... . In each line, a maximum
of one DCIP650-... may be used.
In a multiple-line system with
2lines, this means that 60users
can be called form a door station.
Calling and door release via the
Software Client DCIPSC600-....
The Software Client must be
installed on every PC which receives
calls. The door call is switched via
the DCA740-... to the telephone
system. A connected telephone can
accept the door call.
Call functions of the Software
Client 3-tone chime as standard, a
dedicated *.wav file can be assigned
for each call tone.
It is not possible to listen in to an
existing call from other PC users in
the network. The door is opened by
the called PC user using a “virtual
door release button”, the light
switching function is actuated using
a “virtual light button”. The door
call can be muted with an optical
display on the monitor.
Supplementary functions
• Additional PC users can be
implemented with an additional line.
• Up to 10 PC users can be called in
parallel with a call button from the
door station. Up to 49/45 PC users
are possible at one
IPVS 600-... . Reduction to 45 PC
users can result if 10 or more PC
users are configured as parallel
devices.
Remarks
a) The TR603-... (12VAC, 1.3A)
can supply 1door release button
and max. 24bus call button modules
with LED lighting (BTM650-01, -02,
-03 and -04).
With more than 24illuminated bus
call button modules, an additional
TR603-... is required. Current
consumers in the ASdiagram:
Door release appr. 600mA
Camera heating 100mA
LED lighting
Per bus call button module 25mA
b) Door release contact load in the
bus video line rectifier BVNG650-...
max. 15VAC, 30VDC, 2A.
• Light contact load in the bus video
line rectifier max. 15VAC, 30VDC,
2A.
c) Door release 12VAC, use at least
20Ohm (e.g. TÖ615-...).
f) Distance of the BVNG650-.../
SII650-... to the door station max.
100m with J-Y(ST)Y 0.8mm core
material. During installation, ensure
that the door release is laid in a
separate cable. Supply voltage
available from SIVS610-... at the
terminals bv+/cv- 12VDC, max.
300mA.
The DCA740-01 can optionally be
connected to the PBX extension of
a telephone system. Active door
calls can then be routed via the
telephone. The functions of the IP
interface still remain possible.
g) The DCA740-01 can optionally
be connected to the PBX extension
of a telephone system. Active door
calls can then be routed via the
telephone. The function of the IP
interface remains possible.
h) Each SII650-... must be
programmed with the bus
programming software BPS650-...
and the programming interface
PRI602-...USB.