Programming instructions

29
9 Measured values
Measurement values for DoorCom IP,
to be measured using a digital multimeter
Idle status min. max.
Voltage +/ at the SIVS 610-... 24 V DC 30 V DC
Current consumption 500 mA
Conductor lengths
VNG 602-... supplies 1 DCIP 650-... 100 m
VNG 602-... supplies 2 DCIP 650-... 50 m