Installation guide

6
SB-232 Config Tool Parameters Configuration
Figure 6
After double click the icon of BT1 as BT RS232 Config
Tool, the configuration screen will be pop-up as the
above picture.
A. COM Port Select COM port number, you have to
avoid the port conflict with other device in computer and
use available port number
B. Device Name
Select device name is for identify each one device and
you can follow the name by tool access or retyping the
new name by yourself.
C. Local Address
Local address will be automatically changed after finishing
the parameter configuration to apply.
D. Peer Address
Peer address is for two or more devices to communicate
in a same network address.