Installation guide

9
Rebuilding a Failed Mirror Set
If a SPARE drive was not configured, the steps below will
guide you in rebuilding a failed mirror set.
1. As the BIOS boots press F3 when prompted to enter
the RAID BIOS.
2. Press F1 to dissolve an Array.
3. Press the number of the Mirrored array to be
dissolved.
4. Press Y to confirm. Be sure you delete the correct Array.
5. Press ESC to exit the RAID BIOS, then immediately
turn off the computer.
6. Replace the bad drive with a new hard drive of
equal or greater size, then restart the computer.
7. During boot press F3 to enter the RAID BIOS.
8. Press F2 to Create an Array.
9. Press F2 to create a Mirrored Array.
10. Answer N for Automatic setup.
11. Enter the number of the SOURCE (good) drive.
12. Enter the number of the DESTINATION (new)
drive.
13. Answer Y to copy from Source to Destination drive.
14. Answer N to decline Offline Copy.
15. Answer Y to enable Auto-rebuild.
16. When asked Are You Sure?, Press Y to accept.
17. Press ESC to exit the RAID BIOS and reboot the
computer.