User manual

VisualDepth for Visual Plus 316
(c) 2006-09, Saryna Technologies LLC/Advanced Inspection Technology
3.2.1 External Pits
To measure external pits:
1. Place the external probe gauge wire on a good surface next to the pit and press on the
probe so that both reference prongs are touching the surface of the cylinder. The probe
should be perpendicular to the cylinder surface. Press the left foot switch or F4 to set
zero while holding the probe in this position. The Depth value should change to 0.000in.
2. Type in the location of a pit being measured into the Recorded Measurements box. Place
the external probe gauge wire into the pit and press on the probe so that both reference
prongs are touching the surface of the cylinder. The probe should be perpendicular to the
cylinder surface. Press the right foot switch or F6 to record measurement while holding
the probe in this position.
3. You may continue measuring other pits by repeating step 2 as long as the cylinder
curvature is the same. If location is different from previous pits you can enter the new
location into the Recorded Measurements box. New measurements are always added to
the end of the text. If the curvature of the cylinder is different at the new location then
repeat from step 1. An easy way to check if the curvature is the same is to press the
probe against the good cylinder surface as in step 1 and check that the depth is reading
as 0.000in.
4. Once all pits have been measured press Enter to copy text from Recorded