3.3 Care & Maintenance
VisualDepth probe is a sensitive electronic device and requires following care:
1. It is extremely important to prevent damage to the gauge wire on the end of either probe.
If this wire is bent at a sharp angle, remove the two screws attaching probe head to the
probe body. Remove probe head. Using small pliers carefully straighten the wire. Reinstall
probe head. If the wire cannot be returned to it's original shape then the whole probe
should be sent back to the factory for repair. Please do not attempt to repair yourself
without consulting with the factory.
2. Do not cut or put under excessive pressure the probe swivel cable, if the cable breaks the
internal probe will have to be repaired at the factory as a special fixture is needed to
properly tension the cable.
3. The internal probe handwheel should always be between letters B and M. Do not force the
internal probe past either of those two letters. Those letters indicate the usable range of
the swivel and forcing the probe past those letters can put enough tension on the
positioning cable to break it.
4. The objective lens in the internal probe is moulded optical plastic. Do not use any liquid
cleaners to clean the probe. Only use dry compressed air to clear any dust.
5. Periodically check two pivot set screws on sides of the internal probe fork. Make sure