TDS
Sag Flow
Non-sag, even overhead
Product Temperature
Sika® AnchorFix-2 must be at a temperature of between 41 °F (5 °C) to 68 °F
(20 °C) for application.
Dew Point
Beware of condensation.▪
Beware of frost.▪
Open Time
Working & Loading Times
Cartridge
Temperature
T Work (minutes) Base Material
Temperature
T Load (hours)
Minimum 41°F - 14 °F to 32 °F* 24 hours
Minimum 41 °F - 32 °F to 41°F 180 minutes
41 °F to 50 °F 8 41 °F to 50 °F 100 minutes
50 °F to 68 °F 4 50 °F to 68 °F 70 minutes
68 °F to 77 °F 3 68 °F to 77 °F 40 minutes
77 °F to 86 °F 2 77 °F to 86 °F 40 minutes
86 °F 1 86 °F 40 minutes
T Work is the typical time to gel at the highest temperature in the range
T Load is the typical time to reach full capacity
* The design professional on the job is ultimately responsible for the interpretation of the data provided above.
Product Data Sheet
Sika® AnchorFix-2
November 2018, Version 01.03
020205010020000001
5 /
8