Product Data Sheet
PRODUCT INFORMATION
Packaging
10.1 fl.oz. (299 ml)
Shelf Life
12 months from date of production
All Sika AnchorFix®-1 cartridges have the expiry date printed on the label.
Storage Conditions
Cartridges should be stored in their original packaging, the correct way up, in
cool conditions 41 °F to 77 °F (5 °C to 25 °C) out of direct sunlight.
TECHNICAL INFORMATION
Tensile Adhesion Strength
The above values represent mean ultimate values and allowable working loads. The allowable working loads
have been reduced using a safety factor of 4.0 for tension and 3.0 for shear, however, in some cases, such as
life safety, safety factors of 10.0 or higher may be necessary.
1.
Allowable loads must be checked against steel capacity. The lowest value controls.2.
Tabulated data is applicable to single anchors in normal-weight concrete unaffected by edge or spacing
reduction factors. Values are valid for anchors installed into dry concrete in holes drilled with a hammer drill
and ANSI carbide drill bit.
3.
Service temperatures should remain approximately constant. The maximum long term temperature being
122 °F and the maximum short term temperature being 176 °F. Short term temperatures are those that
occur over brief intervals, for example, diurnal cycling.
4.
Linear interpolation is allowed.5.
*The design professional on the job is ultimately responsible for the interpretation of the data provided above.
Service Temperature
Long Term -40 °F (-40°C) min. / 122 °F
(50 °C) max.
Short term (1–2 hours) 176 °F (80 °C)
(ETA 001, Part 5)
For details about adhesive anchoring design refer to the separate
documentation provided: “Technical Documentation Sika AnchorFix®-1” Ref:
870 43 01
Design Considerations
Product Data Sheet
Sika AnchorFix®-1
March 2020, Version 02.02
020205010010000001
2 /
8