SDS

Safety Data Sheet
SikaAnchorFix®1PartA
Revision Date 11/10/2014
Print Date 01/22/2015
5 / 12
OSHA Z-3
TWA
10 mg/m3 /
%SiO2+2
respirable
OSHA Z-3
TWA
250 mppcf /
%SiO2+5
respirable
OSHA P0
TWA
0.1 mg/m3
Respirable fraction
4-methylstyrene 25013-15-4 ACGIH
TWA
50 ppm
ACGIH
STEL
100 ppm
OSHA Z-1
TWA
100 ppm
480 mg/m3
OSHA P0
TWA
100 ppm
480 mg/m3
titanium dioxide 13463-67-7 ACGIH
TWA
10 mg/m3
OSHA P0
TWA
10 mg/m3
Total
OSHA Z-1
TWA
15 mg/m3
total dust
*The above mentioned values are in accordance with the legislation in effect at the date of the
release of this safety data sheet.
**Basis
ACGIH. Threshold Limit Values (TLV)
OSHA P0. Table Z-1, Limit for Air Contaminat (1989 Vacated Values)
OSHA P1. Permissible Exposure Limits (PEL), Table Z-1, Limit for Air Contaminant
OSHA P2. Permissible Exposure Limits (PEL), Table Z-2
OSHA Z3. Table Z-3, Mineral Dust
Engineering measures
: Use of adequate ventilation should be sufficient to control
worker exposure to airborne contaminants. If the use of this
product generates dust, fumes, gas, vapor or mist, use
process enclosures, local exhaust ventilation or other
engineering controls to keep worker exposure below any
recommended or statutory limits.
The engineering controls also need to keep gas, vapor or dust
concentrations below any lower explosive limits.
Personal protective equipment