Datasheet

BASIC SPECIFICATIONS
Fan designation, diagrammic external view, overall and connecting
dimensions as well as design features are shown in Table 1.
The fans are designed for connecting to AC 220-240 V, 50 Hz or
12 V, 50 Hz (depending on the model) power mains.
Rated capacity with respect to the transported air volume:
for the fans with 100 mm exhaust branch pipe diameter:
55 -107 m /h ( ±5%);
for the fans with 125 mm exhaust branch pipe diameter:
108-232 m /h ( ±5%);
for the fans with 150 mm exhaust branch pipe diameter:
220-348 m /h ( ±5%).
Rated electric power:
for the fans with 100 mm exhaust branch pipe diameter: -5.3/22 W;
for the fans with 125 mm exhaust branch pipe diameter: -9.1/26 W;
for the fans with 150 mm exhaust branch pipe diameter: -20/32 W.
Pressure sound level at 3 m distance does not exceed 40 dB(A).
The fans are designed for operation at the air temperature range
between 0°Ñ and 45°Ñ.
Durability not less than 5 years.
3
3
3
Fan design is regularly being improved, so some models can slightly
differ from those ones described in this manual.
PURPOSE
ans are designed for ventilation of
domestic and similar premises like apartments,
offices, stores, garages, kitchens, bathrooms, toilets
and other rooms, heated during winter time.
ans (except for ) are
designed for air exhaust and are suitable for wall
or ceiling mounting.
-series fans can be used both
for supply and exhaust ventilation and are to be
installed in ventilation ducts.
ans are designed for continuous operation
with permanent power supply.
F
F SIKU1/SIKU2/SIKU3
SIKU1/SIKU2/SIKU3
F
EN