User Manual
IMPORTANT: The range and proper operation of any wireless device
will vary depending on its surroundings. It is very important that each
CO5-SS detector is tested with each receiver intended for alarm.
Detector Description
• LIsted to UL Standard 2034
• CO sensitivity is evaluated to UL 2034
• Local sounder
• Dual LED’s
• Test/Hush button
• Functional Gas Test
• Surface mount to wall or ceiling
• Optional drywall anchors included
The CO5-SS contains a piezoelectric horn which generates the ANSI
S3.41 temporal 4 pattern in an alarm condition (see note below Table
1 for temporal 4 pattern). In alarm, a message is also sent to a pro-
grammed Silent Call Receiver. The alarm message is transmitted every
4 seconds until the carbon monoxide condition has cleared and the de-
tector has reset. During an alarm condition, pressing the detector’s test
button will silence the piezoelectric horn for fi ve minutes. The mounting
base installation is simplifi ed by the incorporation of features compat-
ible with drywall fasteners or other methods that provide a method for
securing the detector in place.
Two LEDs and a sounder on the detector provide local visual and audi-
ble indication of the detector’s status as listed in Table 1.