Specifications

Model 5700 Installation and Operation Manual
9-2 151295
Local programming aborted or ended with errors Trouble System Event LU 1 628 00 000
Periodic test event – normal Test System Event RP 1 602 00 000
Periodic test event – off normal Test System Event RY 1 608 00 000
Initial power up Trouble System Event RR 1 305 00 000
Remote programming ended normally Trouble System Event RS 1 412 00 000
Unable to report to an account Trouble System Event RT Acct # 1 354 Acct # Acct #
Remote programming aborted or ended with errors Trouble System Event RU 1 413 00 000
User has initiated dialer test Test System Event RX 1 601 00
Water release circuit has been disabled Trouble System Event pi Exp. ID SS Pnt # 1 203 Exp. ID Pnt #
Water release circuit has been re-enabled Trouble System Event pi Exp. ID SR Pnt # 3 203 Exp. ID Pnt #
Walk test end Test System Event TE 3 607 00 000
SLC address programming ended; system has been re-
enabled.
Test System Event TE 3 607 00 000
Walk test begin Test System Event TS 1 607 00 000
SLC address programming started; system has been shut
down.
Test System Event TS 1 607 00 000
Printer paper restore Trouble System Event VI Exp ID 3 335 00 Exp. ID
Printer is out of paper Trouble System Event VO Exp ID 1 335 00 Exp. ID
Printer back online Trouble System Event VY Exp ID 3 336 00 Exp. ID
Printer offline Trouble System Event VZ Exp ID 1 336 00 Exp. ID
Auto dialer test communication trouble Trouble System Event YC Line # 1 350 00 Line #
Report to an account successful Trouble System Event YK Acct # 3 354 Acct # Acct #
Auto dialer test communication trouble restore Trouble System Event YK Line # 3 350 00 Line #
Ground fault condition detected Trouble System Event YP Exp. ID 1 310 00 Exp. ID
Ground fault condition restore Trouble System Event YQ Exp. ID 3 310 00 Exp. ID
Battery voltage restore Trouble System Event YR Exp. ID 3 302 00 Exp. ID
Battery voltage low Trouble System Event YT Exp. ID 1 302 00 Exp. ID
Zone Events
Note: Zone events are reported only when "Report by Zone" is selected.
SLC LED Module trouble restore Trouble Zone Event ER 0000 3 333 00 000
SLC LED Module trouble Trouble Zone Event ET 0000 1 333 00 000
Manual pull switch alarm Alarm Zone Event FA Zone 1 115 00 Zone
Detector alarm Alarm Zone Event FA Zone 1 110 00 Zone
Manual pull switch alarm restore Restore Zone Event FH Zone 3 115 00 Zone
Detector alarm restore Restore Zone Event FH Zone 3 110 00 Zone
Manual pull switch trouble restore Trouble Zone Event FJ Zone 3 373 00 Zone
Detector trouble restore Trouble Zone Event FJ Zone 3 373 00 Zone
Positive Alarm Sequence acknowledge switch trouble
restore
Trouble Zone Event FJ Zone 3 373 00 Zone
Auxiliary power trouble restore Trouble Zone Event FJ 0000 3 320 00 000
Notification output trouble restore Trouble Zone Event FJ 1000+Group # 3 320 00 Group #
Manual pull switch trouble Trouble Zone Event FT Zone 1 373 00 Zone
Detector trouble Trouble Zone Event FT Zone 1 373 00 Zone
Positive Alarm Sequence acknowledge switch trouble Trouble Zone Event FT Zone 1 373 00 Zone
Auxiliary power trouble Trouble Zone Event FT 0000 1 320 00 000
Notification trouble Trouble Zone Event FT 1000+Group # 1 320 00 Group #
User initiated a system reset Reset Zone Event OR 1 401 00 000
Water flow switch alarm Alarm Zone Event SA Zone 1 113 00 Zone
Water flow switch alarm restore Restore Zone Event SH Zone 3 113 00 Zone
Water flow switch trouble restore Trouble Zone Event SJ Zone 3 373 00 Zone
Supervisory/Tamper switch trouble restore Trouble Zone Event SJ Zone 3 373 00 Zone
SIA Reporting Format Contact ID Reporting Format
Event Description
Event
Family
Event Class
(System, Zone,
or Point)
Module
ID #
(if any)
SIA
Event
Code
Parameter
(if any)
Qualifier
Event
Code
Group
#
Contact
#