User's Manual

Advanced Configuration Silex Page 29
Part Number 140-00188-180
Chapter 5
Advanced Configuration
The Serial Device Server Serial Device Server is equipped with a default configuration that works with
most serial-to-Ethernet connections. You can modify the settings to suit your installation requirements.
The web browser interface is the recommended method for setting advanced configuration parameters
(some of the advanced configuration parameters are not accessible via ExtendView). However,
regardless of the method to access the configuration parameters, the method for modifying the
parameters is virtually identical.
Factory Default Settings
Table 3 displays the configuration parameter descriptions and settings with the default settings indicated
in a separate column.
Table 3 Factory Default Settings
Parameter Description Settings Default Setting
Character Bits per character 7, 8 8
Flow Flow control None, XON, XOFF,
CTS/RTS
None
Parity Parity None, Even, Odd,
Mark, Space
None
Speed Baud rate of bits per second 300, 600,1200, 2400,
3600, 4800, 7200,
9600, 14400,19200,
38400, 57600, 76800,
115200, 230400,
460800, 921600
115200
Stop Stop bits per character 1, 2 1
Mode Line mode or serial port protocol 232 (SX-500); 232,
422, 485, 485HD (SX-
510)
232
Ecable ECable mode for TCP connections Enable, Disable Disable