Specifications

AN93
68 Rev. 0.9
41 V.34 symbol rate - Symbol rate for V.34 when using
the &T4 and &T5 commands.
0 – 2400 symbols/second
1 – 2743 symbols/second
2 – 2800 symbols/second
3 – 3000 symbols/second
4 – 3200 symbols/second
5 – 3429 symbols/second
A valid combination of symbol rate (S41) and data rate
(&G) must be selected.
Symbol Rate
Allowable Data Rates
2400 2400 – 21600
2743 4800 – 26400
2800 4800 – 26400
3000 4800 – 28800
3200 4800 – 31200
3429 4800 – 33600
505
42 Blacklisting - The Si2493/57/34/15/04 does not dial the
same number more than two times in S44 seconds.
An attempt to dial a third time within S44 seconds
results in a “BLACKLISTED” result code. If the black-
list memory is full, any dial to a new number will result
in a “BLACKLIST FULL” result code. Numbers are
added to the blacklist only if the modem connection
fails. The %B command lists the numbers on the
blacklists.
0 – disabled
1 – enabled
0 (disabled) 0–1
43 Dial attempts to blacklist.
When blacklisting is enabled with S42, this value con-
trols the number of dial attempts that result in a num-
ber being blacklisted.
404
44 Blacklist Timer
Period during which blacklisting is active
180 0–255 seconds
50 Minimum on-hook time – Modem remains on-hook for
S50 seconds. Any attempt to go off-hook is delayed
until this timer expires.
3 0–255 seconds
51 Number to start checking for an outsidePBX line. 1 0–9
Table 31. S-Register Descriptions (Continued)
Definition
S-Register
(Decimal)
Function Default
(Decimal)