HAV Options
Settings which determine how data is displayed on the HAVwear watch
and in the Anlaytics
Enable OFF Button:
An option is available to allow Operators to switch HAVwear OFF. When this mode is enabled, the
operator can prevent the HAVwear from detecting TEP HAV risk exposure data at any time. The OFF
function is included for customers who are concerned about operators picking up exposure points from
non-tool activity such as driving vehicles in rough terrain. The default is set to Disabled, to enable the
OFF button:
On the top tool bar, select Data/Project Manager
On the side menu select SETUP > HAV Options
Tick the Enabled box
Click Save
Exposure Assessment Type:
The majority of HAV reports available with the Analytics software can be viewed as either TEP or SEP or
a combination. TEP (Tool Exposure Points) is calculated based on the vibration level programmed in
the tool tag. SEP (Sensed Exposure Points) is calculated based on the sensed vibration level with the
HAVwear worn on the wrist. It is expected that most organisations would use TEP points initially to
assess their Operator’s risk. In situations where an organisation chooses to select SEP data, the
HAVwear watches will display SEP points and the exposure risk data reported will be based on SEP
points wherever possible. The default is set to TEP, to switch to SEP:
On the top tool bar, select Data/Project Manager
On the side menu select SETUP > HAV Options.
Check the Sensed Exposure Points (SEP) box
Click Save
Operator Sign Out Control:
A control is available to limit the potential for an Operator to sign out more than one HAVwear within a
configurable time period. The default for this control is set to OFF, which makes it possible for any
Operator ID Card to be used to sign out more than one HAVwear.
An Administrator can set a time period of up to 4 hours during which an Operator ID card cannot be
used to sign out a second device.
On the top tool bar, select Data/Project Manager
On the side menu select SETUP > HAV Options
Choose the required time from the drop down menu in the Min Time Between Sign Outs field