11
Operator Training
Ensure operators can demonstrate;
Signing out a HAVwear.
Fitting the HAVwear into the wrist strap and onto the wrist.
An understanding of the HAVwear screen display and alerts.
How to Tag into and out of a SAFE ZONE
An understanding of when to expect a SAFE-DISTANCE warning
Note:
The wrist strap is
personal and
should always be
subject to
appropriate
occupational
hygiene procedures
regarding cleaning
and replacement
Further Support Available:
Operator Posters
Training Video
10
Hardware verification
Further Support Available:
Docking Station Install Guide
Operator Posters
Connect 12V DC power supply to a mains power outlet then connect the power supply output
connector to the Docking Station.
Dock the HAVwear Modules into the charging bays of the Docking Station, ensure that the green
LED on the charging bays illuminates to indicate that communication between the module and the
Docking Station is successful. Failure to communicate will result initially in a flashing red LED
followed by a continuous red LED being illuminated on the charging bay.
Docked modules should be charged for an hour initially before sign out.
Connect the Ethernet RJ45 connector of the Docking Station to a Local Area Network which has a
DHCP server running using a Category 5 or higher ethernet cable (not supplied). Ports 21, 8021,
37729, 37730 and 7000-7099 are used by the Docking Station, network firewalls must be
configured appropriately for successful communication between the Reactec Cloud Server and the
Docking Station.
When the Docking Station has communicated with
the Reactec Cloud Server the date and time shall be
configured and displayed on the Docking Station.