Users Manual Part 2
Operation TP-R-400
34
2.7 Modular System (for Measuring Units PP41.00 and MY21.00 only)
NOTICE
Risk of material damage/damage to the equipment!
• Wipe the probe clean and dry before dismounting!
• Do not use compressed air to clean the touch probe!
• When screwing in the extension, make sure the O-ring is properly seated.
• The probe may be extended by a maximum of 200 mm!
• Align probe in the spindle axis to the spindle centre.
• Calibrate the touch probe.
Modular system
Measuring Unit Extensions
Order Number Length
21.00-VE30
30 mm (1.18”)
21.00-VE50
50 mm (1.97”)
41.00-VE100
100 mm (3.94”)
41.00-VE200
200 mm (7.87”)
O-ring 25x2 Viton
(5642)
Cross adapter
(41.00
-KA)
Measuring unit
(41.00-
PP or
21.00-
MY)
Styli
refer to chapter
1.9.2
C-spanner
(2951)
Up to 5 measuring units can be fitted.
All unused screw holes in the cross
adapter must be sealed using screw
plugs 41.00
-KA-V.