TU600-X TU600-X Technical Manual Version 1.
TU600-X Content Content .......................................................................................................... 2 Introduction .................................................................................................... 7 Related Information .......................................................................................................... 7 Safety first......................................................................................................
TU600-X Specifications .............................................................................................. 22 Product specifications .................................................................................................... 22 Connections: ............................................................................................................... 22 Internal temperature ranges: ......................................................................................
TU600-X Corporate Office Trackunit A/S Gasvaerksvej 24, 4 sal 9000 Aalborg Denmark. www.trackunit.com Copyright and Trademarks © 1998-2019, Trackunit A/S. All rights reserved. Trackunit, Trackunit logo and Trackunit are trademarks of Trackunit A/S, registered in the United States and in other countries. All other trademarks are the property of their respective owners. Release Notice This document is release 1.0 of the TU600-X, Technical Manual.
TU600-X RESELLER’S AND ITS CUSTOMERS’ SOLE RISK, AND TRACKUNIT SHALL HAVE NO LIABILITY WHATSOEVER IN CONNECTION THEREWITH. RESELLER SHALL INDEMNIFY AND HOLD TRACKUNIT AND ITS SUPPLIERS HARMLESS FROM ANY CLAIM BROUGHT AGAINST TRACKUNIT WHICH ARISES FROM RESELLER’S USE OR DISTRIBUTION OF THE PRODUCT IN CONNECTION WITH SUCH ENVIVRONMENTS OR APPLICATIONS.
TU600-X US and Canada certificates: FCC ID: ZMF-TU600 IC: 9746A-TU600 EU certificate: CE mark by EU-Tec certificate: T818625L-01-TEC Australia/New Zealand SDOC approval: RCM mark Trackunit TU600-X, Technical Manual v1.
TU600-X Introduction This document contains the installation guide for the (GSM/LTE M1/NB IOT/GNSS) product type series TU600-X units. This manual is intended for use by system integrators, service providers and application developers (collectively, “Resellers”). It is not intended for end-users of the TU600-X. Any end-user documentation is to be prepared and furnished by the resellers. This manual covers the TU600-X with 60.012 and later firmware operating on: 2.
TU600-X Interference Like all wireless devices, the TU600-X may encounter electrical interference that may affect its performance. Avoid Body Contact with Device during Operation Do not operate the TU600-X in direct contact with your body. Maintain at least 8 inches (20 cm) separation between the device and any parts of your body. Qualified Service Except for batteries and Subscriber Identification Module (SIM) card, the TU600-X contains no user serviceable or replaceable parts.
TU600-X The TU600-X unit cannot be turned off after installation; however, the unit is mostly asleep waiting for either the wake-up timer or activity on the acceleration sensor. The unit operation can continue for approximately 3 to 4 days depending on the charging state of the backup battery. The TU600-X unit is designed for vehicular use only. Electronic Devices Most modern electronic equipment is shielded from RF signals.
TU600-X Posted Facilities The TU600-X unit cannot be turned off after installation, so any vehicle, moving machinery, construction machinery installed with the TU600-X etc. must not enter any facility where posted notices prohibit the use of wireless phones or two-way radios. Aircrafts FCC and FAA regulations prohibit using wireless phones while in the air. Do not carry the TU600-X unit aboard an aircraft as it cannot be turned off.
TU600-X Battery Safety Information Adhere to the following guidelines to avoid the risk of fire or explosion: 1. Dispose of the used battery according to the instructions provided with the battery. 2. Do not drop, puncture, disassemble, mutilate, or incinerate the battery. 3. Touching both terminals of a battery with a metal object will short circuit the battery. Do not carry batteries loosely if the contacts may touch coins, keys, and other metal objects (such as in pockets or bags). 4.
TU600-X Delivered standard content The delivered standard package content includes the following items: 1 x (GSM/LTE M1/NB IOT/GPS)-unit of the model type TU600-X 1 x Mounting cradle. 1 x Li-ion Battery PN 4233.0002 (May already be mounted inside the TU600-X unit) Optional content for generic installation: 1 x Fuse with fuse holder for installation up to 24V DC/ (Max 1A) for TU600-X units delivered with open cable ends.
TU600-X Installing the unit Use location - Children not likely to be present This equipment design typically applies to commercial or industrial equipment expected to be installed in locations where only adults are normally present. Practical installation advice It is very important to be careful when installing the unit, as incorrect installation will reduce the quality of the GPS position reports (Ex.
TU600-X Connections The connections depend on the type of vehicles / machines etc. in which the (GSM/LTE M1/NB IOT)/GPS unit is to be installed. Different variants of the TU600-X device will have only a subset of the connections shown in the table below. Please contact your nearest sales office, distributor or “Reseller” for further information about the availability of other variants in your area.
TU600-X Controller supports Bit Rates up to 1 Mbit/s. Physical Interface specification as referred to by ISO/11898-2. 120R CAN termination optional: Mounted, Not Mounted or controlled by Firmware (CAN configuration). The CAN Interface is only operational when supply voltage (12V / 24V / 48V) is present. Interface cannot operate on internal battery alone. M8 Connector: 1-Wire input The M8 3 pole connector contains 3 signals: 1-wire bus, 5V and Ground.
TU600-X Functionality check Trackunit TU600-X, Technical Manual v1.
TU600-X “Verify my Trackunit” In order to control if the installation of the TU600-X unit has been done correctly, it is possible to use the “Verify my Trackunit” tool. Trackunit TU600-X, Technical Manual v1.
TU600-X Troubleshooting Various error situations are listed below along with some possible solutions. Error Error description code F1 The unit does not answer the SMS command send to it. Possible solutions Verify if the SMS messages are sent to the correct GSM/LTE M1/NB IOT phone number. Check LED status; See the “Functionality check” chapter in this manual. If the TU600-X unit has been delivered with the SIM card mounted. Contact Trackunit support.
TU600-X Installation of the digital output According to the E1 certificate of the TU600-X unit, it is prohibited under any circumstances to use this output to control any equipment that may influence the safety of the construction machinery and earth moving machines/vehicle operation and driving. The output must only be used to control comfort equipment. The example shows a 12V relay function with a 12V DC supply voltage. It is also possible to use a 24V relay with a 24V DC supply voltage etc.
TU600-X SMS commands for output control Function Send SMS Return SMS Description Activation of the output MT OUT1=ON MTC ACK (SERIAL No.) OUT1 ON With this command the output is activated permanently. The output can be deactivated again using the “OFF” command. Deactivation of the output MT OUT1=OFF MTC ACK (SERIAL No.) OUT1 OFF With this command the output is deactivated.
TU600-X For mounting the Trackunit TU600-x in harsh environment, not covered by the compliance statements or areas where pressure cleaning is required the Trackunit HW shield PN 7402.9551 is required for protective mounting. Please order at Trackunit A/S. Recommended fuse holders and fuses up to 48V supply voltages (Can be ordered at Trackunit A/S): a. Supply voltage 12V/24V (Max 30A) i. ATO blade fuses (Max 32V/1A) used with Littelfuse FHAC0002SXJ fuse holder (Standard). ii.
TU600-X support@trackunit.com or phone +45 96 73 74 00 Your inquiry will be processed by our support team and a support ticket number will be created in our system. You will receive your ticket number by email. 2. In case your hardware needs to be sent to us you will receive an RMA form by email from our support team that you must fill out.
TU600-X Internal storage without loss of battery performance -20ºC to +50ºC (Specified by battery cell vendor. This range apply for the TU600-X operated from an external DC supply voltage outside the charging temperature range.) Internal storage with loss of battery performance (Within battery safety limits) -40ºC to +70ºC (According to the MSDS, UN38.3 and IEC62133:2012 testing, it is safe to keep the battery in storage for shorter periods above +50ºC or below -20ºC.
TU600-X LTE-TDD B39: B39: TX 1880-1920 MHz, RX 1180-1920 MHz The marked bands B12/B13 are denoted LTE 700 MHz band lower and upper part. The bands B18/B19 are denoted LTE 800 band lower and upper part for Japan. Trackunit TU600-X, Technical Manual v1.
TU600-X Mechanical specifications Dimensions: Length: Width: Height: Cable length: 122.1 mm 45.65 mm (49 mm incl. mounting cradle) 18 mm (23 mm incl. mounting cradle) 170 - 180 cm Environmental class: IP68 Enclosure material: Non-flammable PP casing and ABS cable connector lid. Weight: 65 g (excluding the cable) Trackunit TU600-X, Technical Manual v1.
TU600-X Approvals and certificates The TU600-X product is certified according to KBA (E1 mark), EU (CE mark), FCC, ISED, ACMA/NZ (RCM mark), JATE/MIC ID (GITEKI mark): FCC ID: ZMF-TU600 IC: 9746A-TU600 10 R – 05 8766 E4857 (TU600-1,-2,-3) (TU600-4,-5,-6,-7,-8,-9) FCC and IC certification statements The TU600-X product contains radio transmitters that comply with CFR 47 Part 15, Part 15.
TU600-X Déclarations selon le CFR 47 Sections 2.1091 et bulletin OET 65 / RSS-102 : Respectant les informations relatives à l'exposition aux radiations de fréquences radio, on déclare que cet équipement respecte les limites d'exposition aux radiations de la FCC aux conditions prévues pour un environnement non contrôlé. Cet équipement doit être installé et fonctionner à une distance minimale de 20 cm entre l'appareil irradiant et votre corps.
TU600-X notices made under section 182 of the Radiocommunications Act and 407 of the Telecommunications Act.
TU600-X Including: Standard Version Description ISO 13766-1, ISO 13766-2 2018 Earth-moving machinery and Construction machinery EN 13309 2010 Construction machinery (Expire 2021-06-30) EN/ISO 14982 2010 Agricultural and forestry machines EN 12895, DIN EN 12895 2015 (EN/IEC 62368-1 + AC/3, A11) 2014, 2015, 2017 EN/IEC 62133 {Ed2} 2012 Industrial trucks - Electromagnetic compatibility Information and communication technology equipment safety Safety requirements for portable sealed secondary
TU600-X Environmental protection without HW shield: Environmental protection with use of HW shield: Trackunit TU600-X, Technical Manual v1.
TU600-X CE marking We, Trackunit A/S hereby declare that the TU600-X product complies with the essential requirements of the RED Directive 2014/53/EU as stated by the EU Declaration of Conformity. EU Certificate and Declaration of conformity (DOC) statements can be downloaded from the Trackunit website: http://www.trackunit.com/en/trackunit/approvals/approvals.htm PTCRB certification for interoperability with mobile networks.