Data Sheet
Table Of Contents
- wgm160p-datasheet-20190225 v2
- ug384-wgm160p-hardware-design-users-guide-20190225
11.5 Locating the Module Close to Human Body
When
using the module in an application where the radio is located close to human body, the human RF exposure must be evaluated.
FCC, IC, and CE all have different standards for evaluating the RF exposure, and because of this, each standard will require a different
minimum separation distance between the module and human body. Certification of WGM160P allows for the minimum separation dis-
tances detailed in Table 11.2 Minimum Separation Distances for SAR Evaluation Exemption on page 41 in portable use cases (less
than 20 cm from human body). The module is approved for the mobile use case (more than 20 cm) without any need for RF exposure
evaluation.
Table 11.2. Minimum Separation Distances for SAR Evaluation Exemption
Certification WGM160P with integrated antenna WGM160P with external reference dipole
antenna
FCC
40 mm 40 mm
ISED 30 mm 40 mm
CE The RF exposure must always be evaluated using the end-product when transmitting
with power levels higher than 20 mW = 13 dBm.
For FCC and ISED, using the module in end products where the separation distance is smaller than those listed above is allowed but
requires
evaluation of the RF exposure in the final assembly and applying for a Class 2 Permissive Change or Change of ID to be
applied to the existing FCC/ISED approvals of the module. For CE, RF exposure must be evaluated using the end-product in all cases.
Note: Placing the module in touch or very close to the human body will have a negative impact on the efficiency of the antenna thus
reducing range.
WGM160P Wi-Fi
®
Module Data Sheet
Certifications