Data Sheet
Table Of Contents
- wgm160p-datasheet-20190225 v2
- ug384-wgm160p-hardware-design-users-guide-20190225
<docnum>: <title>
Recommendations for certification
silabs.com | Building a more connected world. Rev. 0.1 | 14
7 Recommendations for certification
7.1 Module certification regarding port without integrated antenna
WGM160P has been certified with an integrated chip antenna as well as external antennas connected to either RF port or both. The
required antenna impedance is 50 Ω.
Qualified external antenna type
Antenna type
Maximum gain
Connectorized coaxial dipole
2.14 dBi
Any antenna that is of the same general type and of equal or less directional gain as listed in the above table can be used without a need
for retesting in the regulatory areas that have a full modular radio approval (USA, Canada, Korea, Japan). In countries applying the ETSI
standards, like the EU countries, the radiated emissions are always tested with the end-product and the antenna type is not critical, but
antennas with higher gain may violate some of the regulatory limits.
If an antenna of a different type (such as a chip antenna, a PCB trace antenna or a patch) with a gain less than or equal to 2.14 dBi is
needed, it can be added as a permissive change, requiring some radiated emission testing. Antenna types with more gain than 2.14 dBi
may require a fully new certification. Since the exact permissive change procedure is chosen on a case by case basis, please consult
your test house, for example while performing with them the EMC testing of the end-product.
7.2 Locating the Module Close to Human Body
When using the Module in an application where the radio is located close to human body, the human RF exposure must be evaluated.
FCC, IC, and CE all have different standards for evaluating the RF exposure and, because of this, each standard will require a different
minimum separation distance between the Module and human body. Certification of WGM160P allows for the minimum separation dis-
tances detailed in Table 7.1 below in portable use cases (less than 20 cm from human body). The module is approved for the mobile use
case (more than 20 cm) without any need for RF exposure evaluation.
Table 7.1.WGM160P Minimum Allowed Separation Distance From Human Body
Certification
WGM160P with antenna
WGM160P without antenna
6
FCC
24 mm
24 mm
ISED
30 mm
30 mm
CE
The RF exposure must be evaluated using
the end product always when transmitting
with power levels higher than 20mW=13dBm
The RF exposure must be evaluated using the
end product always when transmitting with
power levels higher than 20mW=13dBm
For FCC and ISED, using the Module in end products where the separation distance is smaller than those listed above is allowed but
requires evaluation of the RF exposure in the final assembly and applying for a Class 2 Permissive Change or Change of ID to be applied
to the existing FCC/ISED certificates of the Module. For CE certification, RF exposure must be evaluated using the end product in all
cases.
Note: Placing the Module in touch or very close to the human body will have a negative impact on the efficiency of the antenna thus
reducing range.
6
With external reference dipole antenna