4.2 Operating Conditions
Table 4.2. Recommended Operating Conditions
Parameter Symbol Test Condition Min Typ Max Unit
Ambient operating tempera-
ture
TA
OP
-40 85 °C
Nominal supply voltage to
VBAT
1
V
VBAT
3.0 3.3 3.6 V
Note:
1. Operating outside of the recommended voltage supply range is not supported. The module may disable WiFi transmit functions
when operating outside of this range in order to guarantee regulatory emissions compliance.
4.3 Power Consumption
All currents measured with VBAT = 3.3 V.
Table 4.3. Power Consumption
Parameter Symbol Test Condition Min Typ Max Unit
Continuous TX current, 1
Mbps, max power setting
ITX
MAX
141.3 mA
Continuous TX current,
MCS7, max power setting
ITX
MAX_N
131.4 mA
Continuous RX listen current IRX
MAX
36.6 mA
Continuous RX receive cur-
rent, 1 Mbps
IRX
MAXR
34.5 mA
Continuous RX receive cur-
rent, MCS7
IRX
MAXR_N
38.5 mA
Idle associated current,
DTIM=1
I
DTIM1
UART off TBD mA
Idle associated current,
DTIM=3
I
DTIM3
UART off TBD mA
Idle associated current,
DTIM=10
I
DTIM10
UART off TBD mA
Sleep mode current I
SLEEP
TBD mA
Idle current average I
IDLE
TBD mA