Signs and symbols................................................. Page 7 Description of signal words.......................... Page 7 Customer service..................................................... Page 8 List of pictograms used..................................... Page 8 Upper Arm Blood Pressure Monitor...... Page 10 Introduction................................................................. Page 10 10 11 11 12 12 13 16 16 Intended purpose...............................................
Measuring blood pressure...........................Page Attaching the cuff..............................................................Page Adopting the correct posture...........................................Page Selecting a memory..........................................................Page Carrying out the blood pressure measurement..............Page 31 32 34 35 35 Transferring measurements via Bluetooth®...........................................................Page 37 Evaluating Measurements...
Signs and symbols The following signs are used in the safety section and in these instructions for use. CAREFULLY READ THIS ENTIRE MANUAL, THE SAFETY SECTION AND ALL INSTRUCTIONS AND WARNINGS BEFORE USING THIS PRODUCT. FOLLOW ALL SAFETY NOTES AND WARNINGS TO AVOID HAZARDOUS SITUATIONS AND TO ENSURE CORRECT PRODUCT USE. The following terms indicate safety and property damage messages, and the hazard level.
CUSTOMER SERVICE Call customer service at 1 (844) 543-5872 Visit the Website Customer Service Platform at www.lidl.com/contact-us Visit a LIDL store for further assistance. IAN 366723_2101 P lease have your IAN number ready.
List of pictograms used Observe instructions for use Direct current Storage / Transport Operating Permissable storage and transport temperature and humidity Permissible operating temperature and humidity Permissible storage, transport and operating air pressure Manufacturer Applied part, type BF Serial number IP21 Device protected against foreign matter ≥ 0.49 in (12.5 mm) and against water falling vertically Data transfer via Bluetooth® low energy technology 6723_2101_V3.
List of pictograms used b a Dispose of the packaging and device in an environmentally-friendly manner! Upper Arm Blood Pressure Monitor Introduction Familiarize yourself with the upper arm blood pressure monitor before using it for the first time. Please carefully read the following instructions for use and the important safety notes. Failure to observe the notes may result in personal injury or property damage. Only use the upper arm blood pressure monitor as described and for the indicated purposes.
Using this device, you can quickly and easily measure your blood pressure, save the measurements and display the progression and average of these measurements. The recorded measurements are classified and evaluated graphically. A symbol in the display also warns of possible cardiac arrhythmia. If this symbol lights up in the display after the measurement, please consult your doctor for diagnosis.
measurement values and can also provide average values of previous measurements. The data recorded can support health service providers when diagnosing and treating blood pressure problems and thus contribute to the longterm monitoring of the user’s health. Indication If the user has hypertension or hypotension, they can monitor their blood pressure, pulse values and possible existing cardiac arrhythmia, in a home environment.
a doctor: cardiac arrhythmias, circulation problems, diabetes, hypotension, chills, tremors. Do not use the product in conjunction with a high-frequency surgical unit. Ensure that the cuff is not placed on an arm of a person whose arteries or veins are undergoing medical treatment, i.e. intra-vascular access or intra-vascular therapy or an arteriovenous (A-V) shunt. Failure to observe the following warnings can result in injuries or property damage.
5 6 7 8 9 10 11 Memory button M Settings button SET Function button -/+ START/STOP button Risk indicator Connection for cuff plug Battery compartment 1 4 2 3 9 10 5 6 8 7 10 11 14 US-EN 6723_2101_V3.0_silv_Blutdruckmessgeraet_Content_US.indd 14 17.05.
Display indicators 12 Time and date 13 Systolic pressure 14 Diastolic pressure 15 Pulse value determined 16 Symbol for cardiac arrhythmia Symbol for pulse 17 Memory display: Average value (A), morning (AM), evening (PM), number of the memory space 18 Symbol for replace battery 19 Risk indicator 20 Release air 21 User memory 22 Symbol for Bluetooth® transfer 23 Cuff position control 23 12 22 13 21 14 20 19 18 17 16 6723_2101_V3.0_silv_Blutdruckmessgeraet_Content_US.indd 15 15 US-EN 15 17.05.
Scope of delivery 1 Upper arm blood pressure monitor 1 Upper arm cuff (material no. 164.386 cuff SBM 69) with cuff tubing 4 Batteries 1.
Memory: 2 x 100 memory spaces Dimensions: L 5.3 in (134.5 mm) x W 3.9 in (100 mm) x H 2 in (51,0 mm) Cuff: suitable for an arm circumference between 8.7 in and 16.5 in (22 cm and 42 cm) Weight: 0.
Data transfer via Bluetooth® low energy technology: The product uses Bluetooth® low energy technology, frequency band 2.402‒2.480 GHz, maximum transmission power radiated in the frequency band < -1.5 dBm For a list of compatible smart phones, information about the “HealthForYou “ app and software, as well as further details about the devices, please visit: www.healthforyou.
Warning and safety instructions R EAD ALL INSTRUCTIONS. KEEP FOR FUTURE REFERENCE. INCLUDE ALL DOCUMENTATION WHEN PASSING THIS PRODUCT ON TO OTHERS. General warning instructions Failure to observe the following warnings can result in death or serious injuries. The measurements you take are only intended for your information - they do not replace a medical examination! Discuss your measured values with a doctor.
present a choking hazard for infants if swallowed. They should therefore always be supervised. Do not use the sphygmomanometer in conjunction with a high-frequency surgical unit. Do not use the device with a defibrillator. Do not use the device during an MRI scan. Failure to observe the following warnings can result in injuries or property damage. Ensure that the limb is not functionally impaired when inflating the cuff. Do not take measurements more often than necessary.
impact the accuracy of the measurement and lead to measurement errors. Do not use the device outside of the stated storage and operating conditions. This could lead to incorrect measurement results. Do not place the device in pressure receptacles or gas sterilisation devices. Do not allow the device to fall and also avoid stepping on or shaking the device. Do not disassemble the device, as this can lead to damage, malfunctions and faults. Do not use rechargeable batteries.
Protect the device from impacts, moisture, dirt, severe temperature fluctuations and direct sunlight. Do not drop the device. Bring the device to room temperature before taking measurements. If the measuring device has been stored near to the maximum or minimum storage and transport temperature and is brought into an environment with a temperature of 68 °F ( 20 °C), it is recommended that you wait 2 hours before using the measuring device.
they are misused or abused, this may result in leakage, burns, fire, or explosion. Store batteries in a dry place at room temperature. Batteries are sensitive to high and low temperatures. Such thermal exposure may lead to leakage, fire, or explosion. Keep cells and batteries out of reach of children and pets, especially small batteries. Ingestion may lead to choking or acute and serious personal injury. Keep cells or batteries clean and dry both during use and storage.
Remove discharged batteries from product promptly to avoid possible damage from leakage. Choose the proper battery for the intended application. Always take care to correctly insert batteries observing (+) and (-) polarity marks on the battery and the product for which it is intended. Proper polarity must be observed to avoid damage to either product or batteries.
Do not dispose of the battery in a fire. Failure to observe this precaution may result in an explosion. Dispose of batteries properly and in accordance with government regulations. I nformation on electromagnetic compatibility The device is suitable for use in all environments that are listed in these instructions for use, including in the home. In the presence of electromagnetic disturbances, the device may under some circumstances only be useable to a limited extent.
FCC compliance information FCC ID: OU9TMB1891HJ This product complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: 1) This product may not cause harmful interference, and 2) this product must accept any interference received, including interference that may cause undesired operation. Changes or modifications to this product not expressly approved by the party responsible for compliance could void the user‘s authority to operate the product.
• Connect the product into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio / TV technician for help. SAVE THESE INSTRUCTIONS Initial use erify the parts listed in the scope of delivery are complete. V Remove all packaging material. Inserting / Replacing batteries Slide the battery cover off the battery compartment 11 . 10 11 6723_2101_V3.0_silv_Blutdruckmessgeraet_Content_US.indd 27 US-EN 27 17.05.
Insert the four type 1.5 V AAA (Alkaline type LR03) batteries (with the correct polarity) into the device. Please note the marking inside the battery compartment. Carefully close the battery cover on the battery compartment 11 . Do not use rechargeable batteries. Note: if the change battery indicator 18 is displayed continuously, measurement will not be possible until all batteries have been replaced. As soon as the batteries have been removed from the device, the date and time will be reset.
Changing the date / time / time format / Bluetooth® settings Configure the date, hour format and time. It is only in this way that you will be able to correctly save these measurements with the date and time and request them later on. The settings menu can be accessed in two different ways: Before first use and after every battery change: When you insert batteries into the device, you will automatically arrive at the relevant menu.
T he Bluetooth® symbol will be shown on the display. “On” and “OFF” will flash at the same time. Using the function buttons “- / +”, choose whether you want to activate (“On” flashes) or deactivate (“OFF” flashes) Bluetooth® data transfer. Press the SET button 6 to confirm. If Bluetooth® is activated (“On”) data transfer will begin automatically after the measurement has been taken. Note: The battery life is reduced by transfer via Bluetooth®.
Measuring blood pressure Note: To generate an informative profile of the development of your blood pressure and thus guarantee that you will be able to compare the measured values adequately, measure your blood pressure regularly and always at the same time of day. It is recommended that you measure blood pressure twice a day: once in the morning after getting up and once in the evening. You should not eat, drink, smoke or be physically active in the 30 minutes before each measurement.
Attaching the cuff Failure to observe the following warnings can result in injuries or property damage. Only use the device with the original cuff. The cuff is suitable for an upper arm circumference of between 8.7 in‒16.5 in (22 cm and 42 cm). The correct fit should be checked before the measurement is taken using the index markings described below. Place the cuff 1 on a bare upper arm. The blood flow of the arm should not be constricted by clothing etc. which is too tight.
Place the free end of the cuff 1 closely, but not too tightly, around the arm and close the Velcro strip. The cuff 1 should not be too tight. 1 2 Check that two fingers can still fit beneath the cuff 1 . 1 2 This cuff is suitable for you if, after putting it on, the index mark on the outside of the cuff (▼) is within the OK range on the cuff. 1 6723_2101_V3.0_silv_Blutdruckmessgeraet_Content_US.indd 33 US-EN 33 17.05.
Now insert the cuff tubing 2 with the cuff plug 3 into the connector 10 . 3 10 2 If the measurement is being taken using the right upper arm, the air tube should be over the inner side of your elbow. Ensure that you do not press on the air tube with your arm. Adopting the correct posture Note: Stay still during the measurement process and do not talk to prevent the measurement result from being falsified. You can carry out the measurement while sitting or lying down.
In order not to falsify the measurement result, it is important that you stay still and do not talk. Selecting a memory T here are 2 memories available, each with 100 memory spaces, so that you can save the measured values of 2 different people separately. With the device switched off, press the START / STOP 8 . The most recently selected user button memory will flash in the display 4 ‒ this is User 1 in the default settings.
After the full-screen display, the last measurement result saved will be displayed. If no measurement has been saved, the device will display the value of “0”. After you have confirmed the user selection using the START / 8 , the blood pressure monitor autoSTOP button matically begins measuring by inflating the cuff. The measurement is taken while the cuff is being pumped up. As soon as a pulse has been detected, the pulse symbol will be displayed. After this, the cuff air pressure will be released again.
Transferring measurements via Bluetooth® You have the option of transferring the measured values and values saved on your device to your smartphone using Bluetooth® low energy technology. Activate Bluetooth® in your smartphone settings and open the “HealthForYou” app. Note: The “HealthForYou” app must be open for transfer to occur. Add “SBM69” in the app. When connecting for the first time, a randomly generated six-digit PIN code will be displayed on the device over two lines.
Manual transfer Go to save mode (see “Saving, requesting and deleting measurements”). As soon as the average value of all measurements is displayed, a Bluetooth® connection will automatically be established. The data will be transferred and the Bluetooth® symbol will be shown on the display. Switch the blood pressure monitor off by pressing the 8. START / STOP button Automatic transfer If you forget to switch off the blood pressure monitor, it will automatically switch off after one minute.
blood pressure. It occurs when the heart muscle draws together and presses the blood into the vessels. - The lowest number is the diastolic blood pressure, which then occurs when the heart muscle has fully stretched out again and the heart fills with blood. Blood pressure fluctuations are normal. Even on a repeat measurement, observable differences between the measured values can arise. One-time or irregular measurements therefore do not provide a reliable indication of the actual blood pressure.
process with the symbol . This can be an indicator for arrhythmia. Arrhythmia is an illness in which the heart rhythm is abnormal due to errors in the bioelectric system, which controls the heartbeat. The symptoms (skipped or premature heartbeats, slow or rapid pulse) can stem from heart conditions, age, physical predispositions, an excess of luxury foods, stress or a lack of sleep. Arrhythmia can only be diagnosed by a doctor after a physical examination.
Stages of blood pressure levels Systolic (mmHg) Diastole (mmHg) Color Measure Stage 2: ≥ 180 Hypertension ≥ 110 Red Normal < 80 Green Seek medical advice 160–179 100–109 Red Seek medical advice Red Stage 1: 140–159 90–99 Have it Hypertension checked regularly by a doctor Yellow Have it Pre-hyperten- 130–139 85–89 sion checked regularly by a doctor Yellow Check it 120–129 80–84 yourself < 120 Check it yourself Source: U.S.
Note: These standard values merely serve as a general guideline as blood pressure deviates depending on the individual, different age groups, etc. It is important that you consult your doctor at regularly. Your doctor will provide you with your particular values for normal blood pressure as well as the value for when your blood pressure is classified as dangerous. The bar chart on the display and the scale on the device state which range the blood pressure measured is in.
„A“ will flash in the display 4 and an average of all the saved measurements in the selected user memory will be shown. Press the memory button M 5 again to display the average value of the last 7 days for the morning measurement. (Morning: 5.00 am – 9.00 am, display “AM”). Press the memory button M 5 again to display the average value of the last 7 days for the evening measurement. (Evening: 6 pm – 8 pm, display “PM”).
Restoring the device to its factory settings You can delete all of the data saved on the device, e.g. settings or saved measured values, by restoring the device to its factory settings. Proceed as follows: With the device switched off, press the memory button M 5 . You will then be in the most recently selected user memory. „A“ will flash in the display 4 . Now press the memory button M 5 again to switch to the display mode for the average morning value. „AM“ will flash in the display 4 .
Storage Possible property damage! Do not place any heavy objects on the device and cuff 1 . If the product will not be used for more than one month, remove both batteries from the device to prevent possible battery leakage. Do not kink the cuff tubing 2 . Store the product in a dry location (relative humidity ≤ 93 %). High humidity can shorten the service life or damage the product. Store the product in a location with ambient temperatures between -4 °F and 140 °F (-20 °C and +60 °C). 6723_2101_V3.
Troubleshooting Trouble- Problem shooting Solution Er1 The pulse cannot be measured correctly. You have been talking or moving during the measurement process. The cuff was attached too tightly or too loosely. An error occurred during the measurement process. The pump-up pressure is higher than 300 mmHg or the blood pressure measurement falls outside of the measuring range. The batteries are almost dead. Repeat the measurement process. Be sure not to move or talk.
Trouble- Problem shooting OUT Out of maswuremet range Solution - Relax for a moment. - Refasten the cuff and then measure again. - If the problem persists, contact your physician. Disposal Observe the local regulations for material disposal. Dispose of the device and batteries in accordance with local regulations. If you have any questions, please contact the local waste management authorities.
Avoid using this device directly next to other devices or on top of other devices, as this could cause malfunctions. However, if the device must be used in this manner, this device and the other devices must be monitored to ensure they are working properly. Using accessories other than those specified or provided by the manufacturer of this device can increase electromagnetic emissions or decrease the device’s electromagnetic immunity, which can cause malfunctions.
· Tampering with the product (such as removing cover, unscrewing screws etc.) Consequential and incidental damages are also not covered under this warranty. However, some states do not allow the exclusion or limitation of incidental or consequential damages, so this limitation or exclusion may not apply to you. What is the period of coverage and warranty resolution? The warranty is for 3 years from the date of purchase. At our discretion, product will either be refunded or replaced.
· The product and manual in the original package; · A statement of the problem. What must you do to keep the warranty in effect? · Retain the original receipt; · Follow all product instructions; · Do not repair or modify the product. How does state law relate to this warranty? This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. All implied warranties are limited by the duration and terms of this warranty.
The accuracy of this blood pressure monitor has been thoroughly tested and was developed with regard to a long utilizable service life. If the device is used in medicine, technical inspections using the suitable equipment are to be carried out. Precise information on how to test the accuracy of the device can be requested from our service address. We hereby affirm that this product complies with the European RED Directive 2014/53/EU. www.sanitas-online.de/web/de/landingpages/ cedeclarationofconformity.
The Bluetooth® word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks by Hans Dinslage GmbH is under license. Other trademarks and trade names are those of their respective owners. Apple and the Apple logo are trademarks of Apple Inc., registered in the U.S. and other countries. App Store is a service mark of Apple Inc., registered in the U.S. and other countries. Google Play and the Google Play logo are trademarks of Google LLC.
Notes on electromagnetic compatibility The ME EQUIPMENT or ME SYSTEM is suitable for home healthcare environments and so on. Warning: Don’t near active HF surgical equipment and the RF shielded room of an ME system for magnetic resonance imaging, where the intensity of EM disturbances is high. Warning: Use of this equipment adjacent to or stacked with other equipment should be avoided because it could result in improper operation.
or ME SYSTEM with the requirements of Clause 7 (EMISSIONS) and Clause 8 (IMMUNITY). ACCESSORIES may be specified either generically (e.g. shielded cable, load impedance) or specifically (e.g. by MANUFACTURER and EQUIPMENT OR TYPE REFERENCE).
Table 2: Guidance and manufacturer’s declaration – electromagnetic immunity: Immunity test IEC 60601-2 test level Compliance level Electrostatic discharge (ESD) IEC 61000-4-2 ±8 kV contact ±2 kV, ±4 kV, ±8 kV, ±15 kV air ±8 kV contact ±2 kV, ±4 kV, ±8 kV, ±15 kV air Electrical fast transient / burst IEC 61000-4-4 Not applicable Not applicable Surge IEC61000-4-5 Not applicable Not applicable Voltage dips, short interruptions and voltage variations on power supply input lines IEC 61000-4-11 Not a
Immunity test IEC 60601-2 test level Compliance level NOTE UT is the a.c. mains voltage prior to application of the test level. 56 6723_2101_V3.0_silv_Blutdruckmessgeraet_Content_US.indd 56 17.05.
Table 3: Guidance and manufacturer’s declaration electromagnetic immunity: Radiated RF Test IEC61000-4-3 Fre(Test specifica- quency tions for ENCLOSURE PORT IMMUNITY to RF wireless communications equipment) Band (MHz) Service 385 380‒390 TETRA 400 450 430‒470 GMRS 460: FRS 460 710 704‒787 LTE Band 13, 17 800‒960 GSM 800 / 900, TETRA 800, iDEN 820, CDMA 850, LTE Band 5 745 780 810 870 930 6723_2101_V3.0_silv_Blutdruckmessgeraet_Content_US.indd 57 57 17.05.
Radiated RF Test IEC61000-4-3 Fre(Test specifica- quency tions for ENCLOSURE PORT IMMUNITY to RF wireless communications equipment) Band (MHz) Service 1700‒1990 GSM 1800; CDMA 1900; GSM 1900; DECT; LTE Band 1, 3, 4, 25; UMTS 2450 2400‒2570 Bluetooth, WLAN, 802.11 b / g / n, RFID 2450, LTE Band 7 5240 5100‒5800 WLAN 802.11 a / n 1720 1845 1970 5500 5785 58 6723_2101_V3.0_silv_Blutdruckmessgeraet_Content_US.indd 58 17.05.
Table 3: Guidance and manufacturer’s declaration electromagnetic immunity: Radiated RF ModuIEC61000-4-3 lation (Test specifications for ENCLOSURE PORT IMMUNITY to RF wireless communications equipment) Modulation (W) Distance (m) IMMUNITY TEST LEVEL (V/m) 1.8 0.3 27 FM c) ± 2 5kHz deviation 1 kHz sine 0.3 28 Pulse modulation b) 217 Hz 0.2 0.3 9 Pulse modulation b) 18 Hz 2 0.3 28 Pulse modulation b) 18 Hz 6723_2101_V3.0_silv_Blutdruckmessgeraet_Content_US.indd 59 59 17.05.
Radiated RF ModuIEC61000-4-3 lation (Test specifications for ENCLOSURE PORT IMMUNITY to RF wireless communications equipment) Modulation (W) Distance (m) IMMUNITY TEST LEVEL (V/m) Pulse modulation b) 217 Hz 2 0.3 28 Pulse modulation b) 217 Hz 2 0.3 28 Pulse modulation b) 217 Hz 0.2 0.3 9 60 6723_2101_V3.0_silv_Blutdruckmessgeraet_Content_US.indd 60 17.05.