Technical Manual and Replacement Parts List Beverage Dispenser MODEL SKBD105P/CW1 1600 Xenium Lane North, Minneapolis, MN 55441-3787 Phone (763) 923-2441 FORM NO. 36475 REV A 1 Specifications Subject to Change Without Notice.
TECHNICAL MANUAL MODEL SKBD105P/CW1 CREAM DISPENSER INSTALLATION, OPERATION AND MAINTENANCE Thank you for purchasing Silver King food service equipment. Our goal is to provide our customers with the most reliable equipment in the industry today. Please read this manual and the accompanying warranty information before operating your new Silver King unit. Be sure to complete and mail the warranty card within 10 days of purchase to validate your warranty.
Operation Initial Startup After satisfying the installation requirements, the cream dispenser is ready to start. The unit will start when the power cord is connected to a live electrical receptacle. This can be verified by checking the indicator panel on the front of the unit. The indicator should display the current unit temperature. If the unit does not start when the power cord is plugged in, make sure that the switch on the back of the unit is in the ‘on’ position.
3
4
WHEN ORDERING REPLACEMENT PARTS, PLEASE PROVIDE MODEL AND SERIAL NUMBERS 5
Cleaning and Refilling Procedures Removing Valve Insert To remove the valve insert once the beverage container is empty, simply press on the valve slide and remove the valve insert by pulling it straight up. Cleaning Once removed, the valve can be cleaned with a brush and warm soapy water or in a dishwasher. The valve area in the dispenser should also be cleaned with a brush and warm soapy water. Insert New Bag into Container Insert a new beverage bag into the container as shown.
Cleaning and Refilling Procedures Install Container and Bag Place container inside cabinet and guide tube through valve area. Be sure the tube is straight and centered to avoid kinking, which could result in reduced product flow or leaking. Install Valve Insert Push and hold valve slide while inserting the valve insert from above. Cut Tube Cut the tube one inch below the valve.
Troubleshooting Guide Complaint Compressor will not run Compressor runs but no refrigeration Compressor short cycles Compressor runs too much or constantly Cause 1. No voltage at wall receptacle 2. Service cord pulled out of wall receptacle 3. Low voltage causing compressor to cycle on overload 4. Power switch is in “Off” position 5. Inoperative control 6. Compressor stuck 7. Compressor windings open 8. Compressor overload stuck open 9. Relay lead loose 10. Relay loose or inoperative 11.
Noisy Beverage leaking or not flowing 1. Tubing vibrates 2. Internal compressor noise 3. Compressor vibrating on cabinet frame 1. Tube kinked 2. Valve stuck 1. Call service technician 2. Call service technician 3. Call service technician 1. Remove valve and pull tube straight through valve area 2. Clean valve and valve area or call for service Ordering Parts/Service Contact Silver King Refrigeration at 800-328-3329 for technical assistance. Model__________________ Serial No.
10