European Union Compliance
ThissectiondescribesSilverSpringNetworks’compliancewiththeEUR&TTEDirective.
TheAccessPoint1.5iusesaoneWattFHSSradio.Licenseshavebeenissuedasfollows:
Luxembourg
AlicensehasbeenobtainedfromILR(InstitutLuxembourgeoisdeRegulation)tooperate
inLuxembourginthe870876MHzband.
United
Kingdom
AlicensehasbeenobtainedfromOfcomtooperateinUKinthe870876MHzband.
Portugal
AlicensehasbeenobtainedfromANACOMtooperateinPortugalinthe870873MHz
band.
Thisdevicehasbeendesignedtooperatewithandcertifiedforantennasthathavea
maximumgainof3.0dBion900MHz.Antennasthathaveagaingreaterthanspecifiedare
strictlyprohibitedforusewiththisdevice.Therequiredantennaimpedanceis50ohms.
Installationofallantennaradiatingelementsshallhaveaminimumseparationdistanceof20
cmfromallpersonsandmustnotbe
colocatedoroperatinginconjunctionwithanyother
transmitter.
Declaration of Conformity with regard to the R&TTE Directive 1999/5/EC
Thisdeclarationisonlyvalidforconfigurations(combinationsofsoftware,firmware,and
hardware)providedandsupported bySilverSpringNetworksInc.Theuseofsoftwareor
firmwarenotprovidedandsupportedbySilverSpringNetworksInc.mayresultinthe
equipmentnolongerbeingcompliantwiththeregulatoryrequirements.
Power Consumption Idle Maximum
Ethernet 2.5W, 7W
Ethernet with battery 2.5W, 8W
Cellular 2.5W, 12.5W
Cellular with battery 2.5W, 13.5W
Battery Backup Option: > 8 hour operation
Receive Sensitivity
Receive sensitivity is -102 dBm @ 10
-6
BER.
Mounting Kit Options:
Pole Wooden, concrete, light
Other Wall, pad
Approvals:
FCC Part 15.247
Industry Canada RSS-210
Table 1. Access Point specifications (Continued)