Manual

8
GB
Problem Possible Cause Solution
Tool operating slowly
Pressure incorrect Set the correct air pressure according to the specification
Dirt within the mechanism Pour oil into air inlet as per maintenance instructions
Air blockage Operate tool in short bursts to clear blockage
Air leak Check all fittings and hose for air leaks and correct issue by
re-tightening, using PTFE tape or replacing
Blockage in gauze mesh filter Remove Quick Connector (3) and clean mesh filter
Tool seized
Dirt or rust in mechanism Try ‘Tool operating slowly’ solutions
Dirt or rust in mechanism Tap tool gently with a soft mallet
Dirt or rust in mechanism Free mechanism by rotating drive manually when disconnected
from air line
Tool will not stop after trigger
is fully released
Throttle valve O-ring or valve seat damaged Have the tool repaired at an authorised Silverline service centre
If the above troubleshooting solutions fail, contact your dealer or an authorised Silverline service centre.
Troubleshooting
793750_Z1MANPRO1.indd 8 05/07/2013 11:13