User Guide

07
* T1 : Turn on time ( 2 sec. Max.)
* T2 : Rise time ( 20mS Max.)
* T3 : Power good turn on delay time ( 100 < T3 < 500 mS )
* T4 : Switch on time (0.5 sec. Max.)
* T5 : Power good turn off delay time ( 1.0 mS Min.) PS-ON/OFF
* T6 : Power hold-up time (16 mS Min.)
* Power on-off cycle :
When the power supply is turned off for a minimum of 2.0 sec. and turn on again, the power good signal
will be asserted.
A TTL compatible signal for the purpose of initiating an orderly start-up procedure under normal input
operating conditions. During power up, this signal is asserted ( low ) until +5V is under regulation and AC
reaches min. line specification range. After all voltage are going appropriate level, the system may have a
turn on delay of 100mS, but no greater than 500mS. During power off the signal should go to low level
before +5V is out of regulation. The low level is 0 to 0.8V and high level is 4.75 to 5.25V. The " Power Good "
signal can drive up to 6 standard TTL loads.
8. Power Good Signal
Time Diagram Figure 1