The power supply can operate normally at any altitude between 0 to 10000 feet.
6.2 Altitude
Sweep and resonance search for each of X,Y,Z, axis at the sweep.
RATE of 1/OCTAVE/Min.
6.3 Vibration and Shock
7.1 Safety Requirement
CE
7.2 Leakage Current
The AC leakage current is less than 3.5mA when the power supply connect to 253Vac/50Hz .
7.3 Insulation Resistance
The insulation resistance should be not less than 30M ohm after applying of 500VDC for 1 minute.
7. Product Safety
6.1.2 Storage
Temperature
Relative Humidity
-40 to 70 C
20 to 95 % noncondensing
o
Frequency
5-55-10 Hz
Duration
30 minutes
Amplitude
0.35 mm
The power supply shall withstand for 1 minute without breakdown the application of a 60Hz 1500V AC
voltage applied between both input line and chassis (20mA DC cut-off current). Main transformer shall
similarly withstand 3000Vac applied between both primary and secondary windings for a minimum of
one minute.
7.4 Dielectric Voltage Withstand