Owner's manual

Issued Date: 2009-January-19
Copyright © 2008 SilverStone Technology Co., Ltd. All Rights Reserved
3
3.3. INPUT LINENT & POWER FACTOR
3.4. EFFICIENCY
3.4.1 General
Under the load conditions defined in Table 1 and Table 2. The loading condition for testing
efficiency shown in Table 1 represents a fully loaded system. a ~ 50-60% (typical) loaded
system.and a ~ 20-30% (light) loaded system.
Minimum Efficiency for test purposes are considered to be within ±1.0% of nominal.
Table 1. Loading Table for Efficiency Measurement
Table 2. Minimum Efficiency Vs Load
Loading Voltage
Full
load
Typical
load
Light
load
Required Minimum Efficiency 115V 80% 81% 80%
Required Minimum Efficiency 230V 80% 81% 80%
300W (loading shown in Amps)
Loading +12V1 +12V2 +5V +3.3V -12V +5Vsb
(At Full load)
AC input
115V < 3.5Amps – rms
< 2.0Amps – rms
> 0.95
> 0.9
>0.8
>0.75
230V
Input line current P.F.@ Full Load P.F.@ Pin=75W
Full
Typical
Light
7.56
3.78
1.51
8.64
4.32
1.73
11.5
5.75
2.3
10.46
5.23
2.09
0.37
0.18
0.07
1.84
0.92
0.37