A TTL compatible signal for the purpose of initiating an orderly start-up procedure under
normal input operating conditions. During power up, this signal is asserted ( low ) until
+5V is under regulation and AC reaches min. line specification range. After all voltage
are going appropriate level, the system may have a turn on delay of 100mS, but no
greater than 500mS. During power off the signal should go to low level before +5V is
out of regulation. The low level is 0 to 0.8V and high level is 4.75 to 5.25V. The " Power
Good "signal can drive up to 6 standard TTL loads.
9. Power Good Signal
8.4 Dielectric Voltage Withstand
The power supply shall withstand for 1 minute without breakdown the application of a 60Hz 1500V AC
voltage applied between both input line and chassis (20mA DC cut-off current). Main transformer shall
similarly withstand 3000Vac applied between both primary and secondary windings for a minimum of
one minute.
Power on-off cycle :
When the power supply is turned off for a minimum of 2.0 sec. and turn on again, the power good signal will
be asserted.
T1 : Turn on time ( 2 sec. Max.)
T2 : Rise time ( 20mS Max.)
T3 : Power good turn on delay time ( 100 < T3 < 500 mS )
T4 : Switch on time (0.5 sec. Max.)
T5 : Power good turn off delay time ( 1.0 mS Min.) PS-ON/OFF
T6 : Power hold-up time ( 16 mS Min.)
Time Diagram