manual

02
2.3 Max. Input AC Current
The power supply must meet inrush requirements for any rated AC voltage, during turn on at any phase
of AC voltage, during a single cycle AC dropout condition, during repetitive ON/OFF cycling of AC, and
over the specified temperature range. The peak inrush current shall be less than the ratings of its critical
components (including input fuse, bulk rectifiers, and surge limiting device).
3.1 Normal Operation Output
3. Output characteristics
Max. Input Current
8A
Measuring Range
103.5 - 253 Vrms
2.4 Inrush Current
ST50F-ESB, ST40F-ESB provides an efficiency of 82% when measured at full load under 115V/60Hz
condition.
SST-ST50F-ESB
NOTE:
Noise test should be measured with 20 MHz bandwidth frequency oscilloscope. The output terminal
shall add a tantalum capacitor of 10uF in parallel with a ceramic capacitor of 0.1uF.
2.5 Efficiency
Maximum continuous total DC output power should not exceed 500W.
Maximum continuous combined load on +3.3VDC and +5VDC outputs shall not exceed 103W.
Maximum combined load on 12V outputs shall not exceed 450W.
Output
Voltage
+5V
+3.3V
+12V
-12V
+5Vsb
Load
MIN
0.2A
0.1A
0.6A
0.0A
0.0A
Range
MAX
20A
20A
37.5A
0.3A
2.5A
Peak
-
-
-
-
3.5A
Regulation
±5%
±5%
±5%
±10%
±5%
Ripple & Noise
P-P Max.
50mV
50mV
120mV
120mV
50mV