2. DC OUTPUT
2.1 DC voltage regulation
Parameter Range Min Nom. Max Unit
+3.3V
+/-5
+3.14 +3.3 +3.47 Volts
+5V
+/-5
+4.75 +5 +5.25 Volts
+12V1
+/-5
+11.4 +12 +12.6 Volts
+12V2
+/-5
+11.4 +12 +12.6 Volts
-12V
+/-10
-10.8 -12 -13.2 Volts
+5VSB
+/-5
+4.75 +5 +5.25 Volts
2.2 Load ranges
2.2.1 : (560 Watts Load Ratings)
Parameter Min Nom. Max Peak Unit
+3.3V
+5V
+12V1
+12V2
-12V
+5VSB
0.5
0.3
1.0
1.0
0.0
0.0
12.0
24.0
17.0
15.0
0.5
2.0
30.0
30.0
18.0
18.0
0.5
2.0
19.0
19.0
2.5
Amps
Amps
Amps
Amps
Amps
Amps
Notes:
(1) The maximum continuous total DC outputs power shall not exceed 560W
(2) The maximum peak total DC output power shall not exceed 570W
(limited to duty cycle of 1 minute on, 10 minutes off at 40°C ambient).
(3) The maximum continuous load on +5V and +3.3V outputs shall not exceed 180W.
(4) The maximum combined current for the +12V outputs shall be 36A
(5) When +5V load is 28A, +12V (+12V1 and +12V2) minimum load is 2A
(6) When the combined current for the +12V outputs is 29A, the +5V minimum load is 5A.
(7) When the combined current for the +12V outputs is 22A, the +5V minimum load is 2A.
2.3 Output Ripple
2.3.1 Ripple regulation
Parameter Ripple&Noise Unit
+3.3V 80 mVp-p
+5V 50 mVp-p
+12V1 120 mVp-p
+12V2 120 mVp-p
-12V 120 mVp-p
+5VSB 50 mVp-p