manual

6. SAFETY
6.1 Underwriters Laboratory (UL) recognition.
The power supply is designed to meet UL EN 60950-1:2001
6.2 The power supply must bear the German Bauart Mark from TUV.
The power supply is designed to meet TUV EN60950-1:2001
7. ELECTROMAGNETIC COMPATIBILITY (EMC)
7.1 Electrostatic Discharge (ESD) – EN 61000 – 4 – 2 : 1998
7.2 Electrical Fast Transient/Burst (EFT/B) – EN 61000 – 4 – 4 : 1998
7.3 Surge – EN 61000 – 4 – 5 : 1998
7.4 Power Frequency Magnetic Field – EN 61000 – 4 – 8 : 1998
7.5 Voltage Dips – RN 61000 – 4 – 11 : 1998
7.6 Radiated Susceptibility – EN 61000 – 4 – 3 : 1998
7.7 Conducted Susceptibility – EN 61000 – 4 – 4 : 1998
7.8 Voltage Fluctuation – EN 61000 – 3 – 3 : 1995+A1/2001
7.9 EN61000-3-2:2000 harmonic current emissions.
If applicable to sales in Japan or Europe, the power supply shall meet the requirements of
EN 61000-3-2 class D and the guidelines for the suppression of harmonics in appliances and
general use equipment class D for harmonic line current content at full-rated power.
7.10 EN55022 Class B Radio interference (CISPR 22).
7.11 FCC Part 15, Subpart J class B.
8. MTBF
8.1 MTBF (mean time between failures) calculation
The demonstrated MTBF shall be 100,000 hours of continuous operation at 25
°C, full load, 80%
confidence limit and nominal line. The MTBF of the power supply be calculated in accordance
with MIL-HDBK-217F. The DC FAN is not included.
9. MECHANICAL REQUIREMENTS
9.1 Physical dimension
150 x 86 x 140 mm (W x H x D)
9.2 Net weight
2.2 kg