User's Manual
StreamCaster MIMO Radio User Manual 12/19/18
10017C000 Silvus Technologies Confidential Page
90
scan should not be conducted within the same frequency that the mesh network is
operating in.
Center Frequency – Specify the center frequency of the scan.
Sampling Rate – Set the sampling rate of the scan. (0.3Msps recommended)
Antenna Mask – Choose which antenna on the radio to use for scanning. If there are 2
antenna radios in the network antenna 1 or 2 must be chosen.
Duration – Duration of each scan. A longer duration will provide better accuracy but will
take longer to complete.
Approximated time for scan – Approximate time that the network will be down for the
scan to complete.
Figure 44 Zero Span Results