Installation manual
19
Table 2
  
If the “No optical link” or “Error” signals are active the system will not 
function; if the “Warning” signal is active the system will operate but 
it may be unable to read certain input signals correctly. 
SWITCHING ON AND OFF FROM STAND BY
Switching on the system (Fig.17):
•  from the remote control (keys 0-9 ) 
•  from the screen keypad (keys 
▲ and ▼
).
Typically, the picture will appear after 15-20 seconds.
RC
I 2005
LI
G
H
T
?
?
?
0
AUTO
Fig.17
Pressing a key from 1-9 on the remote control selects the corre
-
sponding input; pressing 0 selects the input that was active at the 
time the system was last switched off. 
Switching off the system (Fig.18):
•  from the remote control (key  ) 
•  from the screen keypad (key  ).
RC
I 2005
LI
G
H
T
?
?
?
AUTO
  Fig.18
If you wish to power off the two units completely, wait at least one 
minute  in  stand-by  to  allow  the  units  to  cool  before  setting  the 
mains power switches to the “O” position or unplugging the power 
supply cables. 
If power is disconnected from the Screen unit (e.g. setting the mains 
power switch to the “O” position or inadvertently unplugging the 
power cable), to restart the HTL40 LINK system also power-off the 
DigiOptic™ Image Processor unit and repeat the power-up sequence 
described at points 1 and 5.
If the fibre optic link between the two units is interrupted (e.g. by 
removing one or more cables) to restore normal system operation 
switch off the two units by means of the mains power switches, 
restore the fibre optic connections, and then repeat power-up mode 
steps 1 and 5.