Hydraulic oil shall be 10W30 engine oil.
Auxiliary hydraulics must be two-way (dual-acting) with detent mode.
Auxiliary hydraulics must have selectable low or high flow option from inside cab
System pressure to be a minimum 3,000 PSI.
Four double-acting cylinders must have a minimum 3,300 PSI rating.
Flat faced pressure releasing hydraulic couplers as standard equipment.
Machine must be equipped with a total of 5 hydraulic couplers
(2) 3/4” Couplers for standard flow attachments
(2) 1¼” Couplers for high flow attachments
(1) ½” Coupler for a case drain back to tank
Machine shall be equipped with a ½” and ¾” pressure releasing coupler block.
Machine must come standard with 2
nd
auxiliary circuit with a minimum of 17 GPM
TRACKS
Loader must have two heavy duty rubber tracks with steel belting and steel
mandrills imbedded inside of tracks.
Tracks shall be hydraulically adjusted using a grease gun and require no special
tools
The tracks shall have a block style pattern.
Tracks shall be steel belted “Bridgestone” OEM tracks, delivered with machine.
Tracks must have a minimum track width of 17.7”.
Maximum ground pressure of 4.5 PSI
Tractive effort or draw-bar pull to be a minimum of 11,067lbs.
The tracks must be tucked into machine
The track contact length must be a minimum of 58.9”.
Minimum track contact area of 1,062 square inches.
CAB & SAFETY EQUIPMENT
Operator cab must meet SAE specifications J1040 and J1043 for rollover
protective
structure (R.O.P.S.) and falling object protection (F.O.P.S.), and be of Level II
certification.
Cab must be fully enclosed with heat and air conditioning w/replaceable air filter
Cab must be sealed and pressurized to rating of 70 PA minimum to maintain a
comfortable operating environment
Cab must be furnished with a deluxe high back six-way suspension seat w/three
height adjustments and weight adjustment
Hand and foot throttle shall be standard
Front door of cab must be a glass roll-up door with a wiper and washer.
Roll-up door can be opened regardless of boom attachment position and can be
locked in the open position for operation
Cab must be equipped with a top view window
The top section of the side windows must slide up and down with fixed bottom
side window sections.