Specifications
SECTION
SPECIFICATION DETAIL
COMPLY
YES
NO
A 2,300 degree Fahrenheit (2,300
o
F) refractory ceramic insulation located
between the reflective wall and bottom floor insulates the bottom of the
unit.
High temperature fiber glass insulation not less than two inches (2”) in
thickness insulates the exterior walls of the unit.
All pieces of the outer shell will be of continuous weld construction.
HEATING
SYSTEM
The heat source is a 60,000 BTU liquid propane gas vapor burner.
Temperature is monitored by a thermostat.
The thermostat controls the temperature settings from 175 to 350 degrees
Fahrenheit.
Gas control valve power is supplied by a self-maintaining 750 MV power
pile generator.
An electric Piezo igniter provides manual pilot ignition.
Main gas valve provides the one hundred (100%) percent safety shut-off
feature in the event of pilot failure.
The LPG burner is mounted under the storage bin.
An access panel allows installation, removal and maintenance of the
burner.
A 14 gauge stainless steel panel is incorporated to offer protection from
direct heat and diverts the heat around asphalt hopper bin.
High temperature insulation, reflective aluminum and stainless steel
deflect heat to provide optimum efficiency.
A combination of convection heating and conduction heating which will
provide the energy required to heat the material enclosed in the storage
bin.
Vapor withdrawal from two (2) 30 pound cylinders at the front area of the
unit are provided, the cylinders will supply fuel to the burner system.
The cylinders shall be secured safely for travel by permanently attached
3/16” chains and adjustable turnbuckles.
Approved fuel supply hoses will be supplied with the unit.
Automatic changeover gas controls will be supplied and attached to the
unit.
SHOVELING
PORT
A single shoveling port located at the rear of the unit is provided for
unloading material.
The shovel port must be large enough to accommodate standard use
asphalt shovels.
The doors will be fabricated of welded 16 gauge steel with high
temperature insulation enclosed inside the doors.
The doors travel in a sliding track which is equipped with a safety latch
feature to keep shovel doors open during use.
The shovel port is to be a minimum of 16” high by 16” wide.