Specifications
SECTION
SPECIFICATION DETAIL
COMPLY
YES
NO
HEATING
SYSTEM
A gas control valve controls the fuel flow and power is supplied by a self-
maintaining 750 MV power pile generator.
A solid state electronic igniter provides manual push button pilot ignition.
Main gas valve provides the one hundred (100%) percent safety shut-off
feature in the event of pilot failure.
The LPG burner is mounted under the storage bin.
An access panel allows installation, removal and maintenance of the
burner.
A 14 gauge stainless steel panel is incorporated to offer protection from
direct heat and diverts the heat around asphalt hopper bin.
High temperature insulation, reflective aluminum and stainless steel
deflect heat to provide optimum efficiency.
The combination of insulation and the “stainless steel diverter” enhances
convection heating and conduction heating which will provide the energy
required to heat the material enclosed in the storage bin.
Liquefied petroleum gas fuel is supplied by propane cylinders.
Vapor withdrawal from the cylinders will supply fuel to the burner system.
Provisions for securing two (2) 30 pound cylinders at the front area of the
unit are provided.
The cylinders shall be secured safely for travel by permanently attached
3/16” chains and adjustable turnbuckles.
UL approved fuel supply hoses shall be supplied with the unit.
Automatic changeover gas controls will be supplied and attached to the
unit.
SHOVELING
PORT
A single shoveling port located at the rear of the unit is provided for
unloading material.
The shovel port must be large enough to accommodate standard use
asphalt shovels.
The doors will be fabricated of welded 16 gauge steel with high
temperature insulation enclosed inside the doors.
The doors travel in a sliding track which is equipped with a safety latch
feature to keep shovel doors open during use.
The shovel port is to be a minimum of 16” high by 20” wide.
SHOVEL
BRACKETS
The shovel brackets shall be located on the passenger side of box; they are
a holster type design to aid in the storage of shovels.
The brackets will be permanently attached and capable of securing not less
than two (2) standard asphalt type shovels during travel.
The shovel shall be easily accessible from the rear working area of the unit
(except on dump units).
Two (2) manual peaked top doors form the lid.