User Manual

P/N R64216 v3.1 Page | 15
SRS Data Synchronization is a process in which all impact data are automatically backed-up onto a remote SRS
Data Server in the event there is damage to the SRS Computer hard drive. Daily data synchronization is strongly
recommended. Synchronization only requires an active internet connection. To setup a wireless internet
connection, follow the Windows Network Settings guide. Due to some network security settings it may be
necessary to have your Network Administrator allow traffic through port 2440 to RedZone.riddell.com.
The SRS computer is not water resistant and should be covered in the event of inclement weather. The computer
may remain in use during inclement weather by closing the laptop lid and then closing the Field Case lid to
protect the computer from water damage.
Alert System
The SRS Alert System consists of the Alert Pager that is carried by sideline staff and the Alert Pager Transmitter
that is housed inside the Field Case.
IMPORTANT: To use the Alert System, ensure the Field Case has external 120V AC power and each Alert Pager
is turned on.
To turn on the Alert Pager, press and hold the top button. The Alert Pagers can have audible, vibration, or silent
alert methods and can store up to 25 alerts. The Alert Pager requires 1 AAA battery. The typical battery life of
an Alert Pager is one month. Alert Pagers will “chirp” to indicate a low battery.
Test Alerts can be sent to the Alert Pagers by utilizing the “Send Test Alert” feature through the SRS Software.
Refer to the SRS Software Guide for more information.
If the Alert Pager or Alert Pager Transmitter becomes unresponsive refer to the Troubleshooting Guide (page 47).
There are no serviceable parts to the Alert System.
Field Case Cabling
The SRS Field Case comes fully configured. However, cabling may become unplugged during shipment or travel.
The following Cabling Diagram may be used for reference in the event something becomes unplugged.
NOTE: Care should be taken when lifting out the layers of the Field Case foam to access the SRS cabling.