1) Press and hold the power button on the Player Unit for six seconds until
the yellow LED blinks off once, and release. The red and yellow LEDs
will flash alternately six times. The Player Unit is now in Test Mode.
2) To generate an Alert, press and hold for two seconds until the LED blinks
off once, then release:
The check-in button to generate a Single Alert, or
The power button to generate a Multiple Alert.
3) The red and yellow LEDs will flash simultaneously three times, followed
by the yellow LED flashing as the Player Unit waits to communicate the
Alert to the Alert Monitor. A series of simultaneous LED flashes
indicates that the Alert has been transmitted. Alert transmission should
happen within 20 seconds.
4) Once the Alert has been transmitted, the Helmet Alert Icon should begin
to flash on the Alert Monitor. Highlight “X NEW ALERTS” on the main
menu and press the SELECT button to view the Alert History screen. The
text line of the test alert should be flashing. Highlight it and press the
SELECT button again to view more detailed alert information.
5) To exit Test Mode, press and hold the Check-In button for five seconds
until the red LED flashes off and back on twice, then release. The red
LED will flash five times. Alternately, wait ten minutes without sending
new Test Alerts and the Player Unit will time out of Test Mode and return
to normal operation.
SYMPTOMS & SOLUTIONS
SYMPTOM
POSSIBLE SOLUTION
Player Unit does
not power on.
Player Unit may have unintentionally been
placed in button lock-out mode. Wait ten
minutes, then try again. If the Player Unit still
fails to power on, call Riddell Customer
Service at (800) 275-5338 for instructions
on how to return to a Riddell-authorized
reconditioning center for battery
replacement.