User's Manual
Table Of Contents
- RF Exposure Statement:
- General Notes
- Copyright
- Contents
- Table Index
- Figure Index
- Revision History
- 1Introduction
- 2Package Information
- 3Interface Application
- 3.1Power Supply
- Figure 5: VBAT voltage drop during burst emission
- 3.1.1Power Supply Design Guide
- Figure 6: Power supply application circuit
- Table 7: Recommended Zener diode list
- 3.1.2Recommended Power Supply Circuit
- Figure 7: Linear regulator reference circuit
- Figure 8: Switching mode power supply reference ci
- 3.1.3Voltage Monitor
- 3.2Power on/Power off/Reset Function
- 3.3UART Interface
- 3.4USB Interface
- 3.5USIM Interface
- 3.6PCM Interface
- 3.7SD Interface
- 3.8I2C Interface
- 3.9SDIO Interface
- 3.10SPI Interface
- 3.11Network status
- 3.12Flight Mode Control
- Switch
- 3.1Power Supply
- 4RF Specifications
- 5Electrical Specifications
- 6SMT Production Guide
- 7Packaging
- Appendix
SIM7600SA-H_User Manual_V1.00
2017-10-11
Smart Machine Smart Decision
Table 8: Power on timing and electronic characteristic
Symbol
Parameter
Min.
Typ.
Max.
Unit
T
on
The time of active low level impulse of PWRKEY
pin to power on module
100
500
-
ms
T
on(status)
The time from power-on issue to STATUS pin
output high level(indicating power up ready )
12
13
-
s
T
on(uart)
The time from power-on issue to UART port ready
11
12
-
s
T
on(usb)
The time from power-on issue to USB port ready
11
12
-
s
V
IH
Input high level voltage on PWRKEY pin
0.6
0.8
1.8
V
V
IL
Input low level voltage on PWRKEY pin
-0.3
0
0.5
V
3.2.2 Power off
The following methods can be used to power off SIM7600SA-H.
● Method 1: Power off SIM7600SA-H by pulling the PWRKEY pin down to ground.
● Method 2: Power off SIM7600SA-H by AT command “AT+CPOF”.
● Method 3: over-voltage or under-voltage automatic power off. The voltage range can be set by
AT command “AT+CPMVT”.
●
Method 4: over-temperature or under-temperature automatic power off.
Note: If the temperature is outside the range of -30~+80
℃
, some warning will be reported via AT
port. If the temperature is outside the range of -40~+85
℃
, SIM7600SA-H will be powered off
automatically.
For details about “AT+CPOF” and “AT+CPMVT”, please refer to Document [1].
These procedures will make modules disconnect from the network and allow the software to enter a
safe state, and save data before module be powered off completely.
The power off scenario by pulling down the PWRKEY pin is illustrated in the following figure.
PWRKEY
( Input )
STATUS
(
Output
)
UART Port
USB Port
Figure 11: Power off timing sequence