OWNER’S MANUAL ® Convertible Deep Well Jet Pumps and Tank System 293 Wright St., Delavan, WI 53115 Phone: 1-800-468-7867 1-800-546-7867 Fax: 1-800-390-5351 Web Site: http://www.simerpump.com 4025 0801 Mod. Nos. 2805E-01, 2806E-01, 2810E-01, 2815E-01 Installation/Operation/Parts For further operating, installation, or maintenance assistance: Call 1-800-365-6832 English . . . . . . . . . . . . . Pages 2-14 ©2002 PRINTED IN U.S.A. 1000000171 (Rev.
Safety 2 READ AND FOLLOW SAFETY INSTRUCTIONS! This is the safety alert symbol. When you see this symbol on your pump or in this manual, look for one of the following signal words and be alert to the potential for personal injury: warns about hazards that will cause serious personal injury, death or major property damage if ignored. warns about hazards that can cause serious personal injury, death or major property damage if ignored.
Table of Contents 3 Thank you for purchasing a top quality, factory tested pump. Page General Safety .....................................................................................................2 Warranty ..............................................................................................................3 Replacing an Existing Pump.................................................................................4 New Shallow Well Installation...............................................
Replacing an Existing Pump 4 SHALLOW WELL (Figure 1) Control Valve Port plugged Pressure Gauge Port plugged hold Hazardous voltage. Can shock, burn or kill. Disconnect power to pump before working on pump or motor. e ous To H 1. Drain and remove the old pump. Check the old pipes for scale, lime, rust, etc., and replace them if necessary. Shallow Well Injector Installed Fro mW Drive Pipe Port plugged ell 4026 0801 Figure1: Shallow Well Setup 3.
New Shallow Well Installation 5 SHALLOW WELL JET PUMP INSTALLATIONS Relief Valve To Household Water System Check Valve • Have a vertical depth between the pump and the water being pumped of 25’ or less. • Have one pipe from the well to the pump case. • Can be installed in a bored or drilled well, or in a driven well.
New Shallow Well Installation Relief Valve To Household Water System Check Valve Suction Pipe From Well Priming Tee and Plug 10' Min. Not to Scale Foot Valve 5–10' Screen 6 INSTALLATION FOR SURFACE WATER (Figure 6) 1. The pump should be installed as close to the water as possible, with the fewest possible fittings (especially elbows) in the suction pipe. The suction pipe should be at least as large as the suction port on the pump. 2. Assemble a foot valve and suction pipe.
New Deep Well Installation Relief Valve 7 2” WELL (Figure 8) To Household Water System 1. Install the control valve, pressure gauge, and deep well plug in the pump body. See Figure 2. Purchase Model MDWC Deep Well Conversion Kit to obtain these parts. Well Head 2. Mount the pump as close to the well as possible. Drive Pipe To Well 3. Install a flexible pipe between the well head and the pump so the connection will be correct. Connect small port to small port and large port to large port.
Electrical 8 Hazardous voltage. Can shock, burn or kill. Disconnect the power before working on pump, motor, pressure switch, or wiring. Your Motor Terminal Board (under the motor end cover) and Pressure Switch look like one of those shown below. Convert to 115 Volts as shown. Do not change motor 230 Volt to 115 Volt Conversion. Move plug to change voltage.
Electrical 9 Connection Procedure: 1. Connect the ground wire first as shown in Figure 11. The ground wire must be a solid copper wire at least as large as the power supply wires. 2. There must be a solid metal connection between the pressure switch and the motor for motor grounding protection. If the pressure switch is not connected to the motor, connect the green ground screw in the switch to the green ground screw under the motor end cover.
Preparing to Start the Pump – Deep Well 10 Burn hazard. Never the run pump dry. Running the pump without water may cause pump to overheat, damaging seal and possibly causing burns to persons handling pump. Fill pump with water before starting. Hazardous pressure. Risk of explosion. Never run the pump against a closed discharge. To do so can boil water inside pump, causing hazardous pressure in unit, risk of explosion and possibly scalding persons handling pump. Remove the control valve.
Preparing to Start the Pump – Shallow Well 11 If you were unsuccessful, please refer to the Troubleshooting section or call our customer service technical staff. Burn hazard. Never run pump dry. Running the pump without water may cause the pump to overheat, damaging the seal and possibly causing burns to persons handling the pump. Fill the pump with water before starting. Remove the fill plug and fill the pump and piping. Hazardous pressure. Risk of explosion. Never run pump against closed discharge.
Troubleshooting SYMPTOM Motor will not run Motor runs hot and overload kicks off Motor runs but no water is delivered* * (Note: Stop pump; then check prime before looking for other causes. Unscrew priming plug and see if water is in priming hole).
Repair Parts 13 Models 2805E-01 2806E-01 2810E-01 2815E-01 1 14 2 19 14 16 20 3 4 5 6 10 18 7 15A 12C 89 16 15 17 12B 12A 14 11 12 7A 4024 0801 13 9 4037 0801 Model MDWC Deep Well Conversion Kit - Purchase Separately. Key No.
Repair Parts 14 Model 2806E-01 2 1 3 4 9 8 7 3 5 6 4024 0801 w/ Tank Key No. Part Description 2806E-01 1/2 HP Qty. 1 2 3 4 5 6 7 8 9 ** Pump Fitting, PVC Clamp, Hose Hose, Clear Fitting, 90 Deg. Tank, HT7, 15 Gal. Horiz. Carriage Bolt, 5/16 -18 X 1-1/4” Washer, 3/8” Reg. 1-7/16” Nut, 5/16 -18 Pump/Tank Assembly 1 1 2 1 1 1 2 2 2 1 † 322-006 U19-55SS 403-005 322-004 998-010 U30-231ZP U43-62ZP U36-37ZP 992-871 † ** For pump parts see the Previous Page.